1.   When this room heater is not properly installed, a house 

fire may result. To reduce the risk of fire, follow the instal-

lation instructions. Contact local building or fire officials 

about restrictions and installation inspection requirements 

in your area. 

2.   Wear gloves during installation to avoid injury from sharp 

edges on the insert and/or its parts.

3.   This unit is designed and engineered to burn only dry, well-

seasoned wood. Burning wet wood will greatly reduce your 

inserts efficiency, produce excessive amounts of smoke 

and can cause dangerous chimney fires due to creosote 

build-up.

4.   Before opening the door, the draft control must be fully open 

to avoid possible combustion flash (ignition of hot volatile 

gases as the door is opened).

5.   Never use gasoline, gasoline-type lantern fuel, kerosene, 

charcoal lighter fluid, or similar liquids to start or ’freshenup’ 

a fire in this heater. Keep all such liquids well away from 

the heater while it is in use. DO NOT USE CHEMICALS OR 

FLUIDS TO START THE FIRE.

6.   While burning, fuel utilizes oxygen from the air in the room. 

Be sure to allow an adequate amount of fresh air into the 

room where the insert is burning.

7.   The outside surface of the insert will be hot while burning 

properly and can set items like clothing and curtains on fire. 

Keep furnishings and other combustible materials away 

from the insert. Using the heat from the insert to dry wet 

clothing can be hazardous if clothes are placed too near 

the surface of the insert.

8.   HOT WHILE IN OPERATION.  KEEP CHILDREN, CLOTHING 

FURNISHINGS AND COMBUSTIBLE MATERIAL A CONSIDER-

ABLE DISTANCE AWAY.  CONTACT MAY CAUSE SKIN BURNS. 

Do not allow children to play near the insert without close 

supervision. Do not touch the insert while it is burning. 

Use extreme caution while the unit is in use. Surface tem-

peratures become dangerously hot and can cause serious 

burns.

9.   Do not allow anyone to operate the insert who is not familiar 

with the operating instructions.

10.  Attempts to achieve heat output rates that exceed insert 

design specifications can result in permanent damage to 

the insert. Never leave your insert unattended on high burn 

rates. This may cause overfiring. Overfiring the insert may 

cause a house fire. If the insert glows, you are overfiring.

11.  Keep a water hose or hand-operated fire extinguisher close 

for safety.

12.  Smoke Detectors - Since there are always several poten-

tial sources of fire in any home, we recommend installing 

smoke detectors. If possible, install the smoke detector in 

a hallway adjacent to the room (to reduce the possibility 

of occasional false activation from the heat produced by 

the insert).  If your local code requires a smoke detector 

be installed within the same room, you must follow the 

requirements of your local code. Check with your local 

building department for requirements in your area.

IMPORTANT SAFETY AND WARNING 

INFORMATION

READ THIS MANUAL IN ITS ENTIRETY AND UNDER-

STAND THESE RULES TO FOLLOW FOR SAFETY.

13.  Inspect your chimney at least once a month during the burn-

ing season to check for soot and creosote accumulations. 

Any accumulations over 1/8” thick should be removed by 

a professional chimney sweep. Do not attempt to burn out 

heavy creosote accumulations with a hot fire. If large ac-

cumulations are occurring, review your burning procedures.

14.  If a creosote fire should develop, the fire department should 

be called immediately and then attempts should be made 

to control the fire until assistance arrives. If a “runaway” 

fire should develop causing over-heating of the insert, the 

door and draft regulators should be closed immediately. 

The fire should die down once deprived of oxygen. After a 

severe chimney fire, the complete chimney system should 

be checked before further use.

15.  Do Not Use Grate Or Elevate Fire - Build Wood Fire Directly 

On Hearth (firebrick). Do not use andirons or other methods 

of supporting the fuel. 

16. Please read this entire manual before you install and use 

your new room heater. Failure to follow instructions may 

result in property damage, bodily injury, or even death.

17.  Check all local building and safety codes before installation. 

The installation instructions and appropriate code require-

ments must be followed exactly and without compromise. 

In the absence of local codes the following standards and 

codes must be followed.

18.  In the U.S.A, install in accordance with the National Fire 

Protection Association’s Code, NFPA 211, Standards for 

Chimneys, Fireplaces, Vents and Solid-Fuel-Burning Appli-

ances, or similar regulations, may apply to the installation 

of a Solid-Fuel-Burning appliance in your area. In Canada, 

the guideline is established by the CSA Standard, CAN/

CSA-B365-M93, Installation Code for Solid-Fuel-Burning 

Appliances and Equipment.

19. 

DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY 

AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY 

APPROVED FOR SUCH INSTALLATIONS.

20. WARNING: BURNING IMPROPER FUEL (I.E. CHARCOAL) 

CAN RESULT IN CARBON MONOXIDE POISONING, WHICH 

MAY LEAD TO DEATH!  

21.  Carbon Monoxide Poisoning – early signs of carbon monox-

ide poisoning resemble the flu with headaches, dizziness, 

or nausea.  If you have these signs, get fresh air at once!  

Have the heater inspected by a qualified service technician.  

Some people are more affected by carbon monoxide than 

others.  These include pregnant women, people with heart 

or lung disease or anemia, those under the influence of 

alcohol, and those at high altitudes.

22. Failure to use manufacturer provided parts, variations in 

techniques and construction materials or practices other than 

those described in this manual may create a fire hazard and 

void the limited warranty.

23.  Do not make any make-shift compromises during installa-

tion. Any modification or alteration may result in damage 

to the appliance or dwelling and will void the warranty, 

certification and listings of this unit.

24.  These appliances are designed as supplemental heaters. 

Therefore, it is advisable to have an alternate heat source 

when installed in a dwelling.

25.  Do Not Overfire – If Heater or Chimney Connector Glows, 

You Are Overfiring.

26.  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING 

ANOTHER APPLIANCE.

27.  DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH 

AS GASOLINE, NAPHTHA OR ENGINE OIL.

Содержание Striker C160

Страница 1: ...éro de la pièce 900100 00 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual before installing and using your wood fireplace insert Failure to followtheseinstructionscouldresultinpropertydamage bodilyinjury orevendeath Contactyourlocalbuildingorfireofficialstoobtain a permit and inform...

Страница 2: ...arth Protection 8 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instructions provided in this manual PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE Chimney Requirements 9 Installation Procedure Masonry Chimney 9 Positive Flue Connection 10 Installation Procedure Factory Built Zero Clearance Fireplaces 11 Fire...

Страница 3: ...heburn ing season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professional chimney sweep Do not attempt to burn out heavy creosote accumulations with a hot fire If large ac cumulationsareoccurring reviewyourburningprocedures 14 Ifacreosotefireshoulddevelop thefiredepartmentshould be called immediately and then attempts should be made to cont...

Страница 4: ...ay include Cracking warping or burning out of components plated accessories may turn color stove glass may develop a haze which will not come off with cleaning Overfiring of a stove or fireplace insert is a condition where excessive temperatures are reached beyond the design capabilities of the appli ance The damage that occurs from overfiring is not covered under the manufacturer s limited warran...

Страница 5: ...heater In well insulated and weather tight homes it may be difficult to establish a good draft up the chimney caused by a shortage of air in the home The lack of air is caused by many common household appliances which exhaust air from the home such as a furnace heat pump air conditioner clothes dryer exhaust fans fireplaces and other fuel burning appliances Also the combustion process of this heat...

Страница 6: ... The final step of the baffle board baffle blanket installation will be installing the front baffle boards The front baffle boards will be the two remaining baffle boards which are the larger two baffle boards of the four baffle board kit They will be installed with the 7 3 8 dimension from the front to rear of the firebox Start by setting the back side of the board on the rear baffle making sure ...

Страница 7: ...to the side 8 200mm This is measured from the sides of the door opening in the USA and from the sides of the insert in Canada 2 J Maximum lintel depth without flue offset or smoke deflector This appliance may be installed in a bedroom in the United States Model A B C D E 1 C A160 USA 24 CAN 660mm USA 15 CAN 450mm 20 508mm 12 305mm USA 4 1 2 CAN 200mm C A160 with mantel and or side shields 16 406mm...

Страница 8: ...ken from Tables 2 and 3 Using the k formula FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alternate material kM x thickness alternate k value per inch of listed material TM of listed material kL material TL TM inches kM x TL 84 TM inches 35 x 375 84 156 inches 417 x 375 Answer TheminimumrequiredthicknessoftheMicore1...

Страница 9: ...are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug against thefireplaceface Thenwiththelocationselectedremovethesurround panels and level the fireplace insert with the leveling bolts using a 3 4 19 mm socket extensions to reach the bolt head and a ratchet 8 Glue the insulation around the outer edge of both the top and side surroun...

Страница 10: ...l off plate i e 22 gage sheet steel in the fireplace throat using masonry screws Other acceptable methods include packing noncombustible material i e high temp fiberglass or ceramic insulation around the vent pipe or using a flue adapter Whatever seal off method is used it must effectively seal the area to prevent room air passage to the chimney cavity of the fireplace Offset Boxes Offsets can be ...

Страница 11: ...3 76 mm long bolts with the head up through the nuts attached to the insert on the lower rear corner of each side This will allow you to level the insert when placed into the fireplace Measure from the front of the top surround mount to the center of the flue Determine if there is an alignment problem in connecting a liner from the chimney to the insert s flue If there is an alignment problem conn...

Страница 12: ...UR INSURANCE COMPANY Chimney Liner Installation Place the insert into the fireplace making sure to center it side to side Slide the insert in until the surround mounts are approximately 1 2 13 mm from the face of the fireplace where the surround panels cover Lower the chimney and make attachment to the insert Level the fireplace insert by using a 3 4 socket and a long extension and adjusting the b...

Страница 13: ...ed while the front door is slightly open Once kindling is burning well larger pieces of wood may be added then the door should be fully closed if there was the need to keep it slightly open during start up DO NOT LEAVE THE APPLIANCE UNATTENDED WHILE THE FRONT DOOR IS SLIGHTLY OPEN CAUTION Do Not alter the adjustment range of the draft control for increased firing for any reason Operate only with f...

Страница 14: ...clockwise until it clicks OFF Blower Speed Control Knob rheostat Manual Auto Rocker Switch TWO S MANUAL WHT NOTE SWITCH CONDITIONS GIVEN AT ROOM TEMPERATURE N C NORMALLY CLOSED N O NORMALLY OPEN FEMALE DISCONNECT MALE DISCONNECT STUD CONNECTION TWO POSITION SWITCH MANUAL TEMPERATURE AUTO RES TEMPERATU SWITCH N POWER CORD RED RED YLW BLK WHT GRN NOTE SWITCH CONDITIONS GIVEN AT ROOM TEMPERATURE N C ...

Страница 15: ... down to 275 to 400 degrees on Elite inserts locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with the draft open for a few minutes to ignite the wood All IHP stoves and fireplace inserts are EPA tested for emissions at low burn with the air control completely closed Whether or no...

Страница 16: ...e E clip from the upper hinge pin Remove upper hinge pin by pulling up while holding the op posite side of the door Lift door out of the lower hinge pin and place face down on a soft surface Step 2 Remove Door Back Screws 6 ea Using a 5 32 allen wrench remove the 6 retainer screws from the faceplate To locate screws peel back the door gasket as necessary Step 3 Disassemble Door Assembly Flip door ...

Страница 17: ...ve and Clean Glass above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blanket is pushed back flush with the front of the baffle boards 2 Check the chimney for blockage due to creosote See Creosote section on Page 5 3 Check draft See POOR DRAFT section above WOOD BURNS 1 The draft control must be closed fur...

Страница 18: ... the baffle assembly DO NOT Close the door tightly during Burn In period DO Be sure to clean any fingerprints from optional accessories that have plated surfaces before burning the appliance Clean the plated surfaces only with household type glass cleaner and a very soft cloth DO Consult local building department if other than recommended clearances are desired DO Read instructions for the baffle ...

Страница 19: ...placement Power Cord 19 H8074 UHPII Blower Cage Snap Switch Black H8075 UHPII Blower Cage Snap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Switch Brushed Gold H8078 UHPII Blower Cage Snap Switch Brushed Nickel 29 H8064 Snap Switch w Gasket and Screws 32 H8066 Control Switch Manual Off Automatic C160 AND SWI160 INSERT PARTS 33 71138 Small Flange Screw Black S...

Страница 20: ...20 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts ModelS C160 and CA160 ...

Страница 21: ...21 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 Replacement Parts ModelS C160 and CA160 Door Parts Blower Parts ...

Страница 22: ...3 4 x 40 71079 WFT2948 N Nickel 30 3 4 x 48 BLOWERS Cat No Model Description H7907 WSINS BLWR B SS Blower Insert Black H7908 WSINS BLWR G SS Blower Insert Gold H7909 WSINS BLWR N SS Blower Insert Nickle H7910 WSINS BLWR BN SS Blower Insert Brushed Nickel H7911 WSINS BLWR BG SS Blower Insert Brushed Gold ETCHED GLASS 71073 Glass Arch Sailboat Arch Sailboat 71069 Glass Arch Cattail Arch Cattail 7107...

Страница 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL ModelS C160 and CA160 2013 2014 2015 Innovative Hearth Products LLC 1508 Elm Hill Pike Suite 108 Nashville TN 37210 ...

Страница 24: ...24 NOTES ...

Страница 25: ...g a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry seasoned wood only c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting f...

Страница 26: ...ance 2 The Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or application of this system please contact your dealer Innovative Hearth Products LLC IHP 1508 Elm Hill Pike Suite 108 Nashville TN 37210 www IronStrike us com Pro...

Отзывы: