![IronStrike Madison Park MPI27 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/ironstrike/madison-park-mpi27/madison-park-mpi27_installation-and-operation-manual_2091492023.webp)
23
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 20
Electronic Gas Control Valve
SIT Proflame, Stepper
Electronic Pilot
Assembly
Unit-Mounted
On/Off Switch
Intermittent/Standing Pilot Mode
(On/Auto Pilot Mode Switch)
This appliance can be switched from intermittent ignition to a standing
pilot simply by using the remote to switch from IPI to CPI. This is done
when the remote is in the off position. Press the mode key and use the
up/down arrow key to change between IPI and CPI. To save energy,
switch to intermittent mode. To have a standing pilot which will help
startup during cold climate conditions by warming the flue and the glass,
switch to standing pilot.
The standing pilot mode is indicated by a pilot that comes on and remains
lit when the fireplace is off.