9. CONNECTING IN KEYBOARD EMULATION MODE

10. CONNECTING IN READER EMULATION MODE

To set an adapter into keyboard emulation mode, use Prg_RDAII.exe software to load
USB_HID_Vxx.rom custom ROM into the adapter. The necessary files are located in the drivers
distribution archive.
When the custom firmware has been flashed, the PC operating system detects a new keyboard.
Typically, to get information via COM Port, an application had to open it as an additional device
and handle the data on its own. With keyboard emulation, the transferred information gets
uploaded into operating system's keyboard buffer without using COM ports just like typing on a
standard keyboard.
With a reader connected like that, an acquired card number can be automatically transferred
straight into any application (such as Excel, Word, a browser etc.).
This method enables to enter card codes directly into active field of ACS software which does
not support reader connections via a virtual COM port, or when working on a remote terminal.
Also, this method enables converting any external card reader into a desktop-based one.

Note: The described below features are additional, and full operational compatibility with other
devices is not guaranteed.
For example, under control of external software, the adapter can emulate a reader connected via
iButton or Wiegand. This allows using a PC to initialise the memory of standalone controllers which
lack the direct memory write capability.
Another example is using this adapter in a car park ACS. External automatic number plates
recognition (ANPR) software is running on a PC with a connected video camera. The codes
corresponding to car number plates are transferred by this adapter via iButton or Wiegand
protocol straight into the controller operating the exit barrier.
More examples can be found on this adapter webpage at http://www.ironlogic.

.

me

An example of adapter connection to a controller in the reader emulation mode via iButton
protocol is shown at the figure below.

LED

DALLAS

BUTTON

LOCK

GROUND

DOOR

5

Z-5R

+12

GROUND

BEEP

page 7

Z-2 BASE

www.ironlogic.me

Содержание Z-2 BASE

Страница 1: ...rmat as if from a standard keyboard Custom firmware version required Connecting to an external controller via a card reader emulation iButton or Wiegand protocols to transmit acquired cards keys serial numbers to that controller by commands from a PC Most of the listed above tasks are solved by the BaseZ5R software available FREE from http www ironlogic Because the adapter draws quite significant ...

Страница 2: ...tocol Auto Casing material Plastic Dimensions mm 64 x 64 x 19 Gross weight 150 g Device dimensions are presented in Figure 64 64 19 58 58 5 12V Power output for external devices GND Ground power DATA 0 iButton DATА0 for Wiegand DATA 1 iButton DATA1 for Wiegand LED G Green LED external control by commands from PC LED R Red LED external control by commands from PC BEEP Buzzer external control by com...

Страница 3: ...RATION Note COM port settings Baud rate 19 200 baud Data bits 8 Parity bits None Stop bits 1 Flow control None ASCII commands Control commands may change if the firmware is changed I Adapter Information R iButton Card Re read A и Z Set and Clear 12 V on POWER output S и X Set Low 0 V and High 5 V levels of BEEP signal D и C Set Low 0 V and High 5 V levels of LED R signal F и V Set Low 0 V and High...

Страница 4: ...t 1 terminals have a life of about 200 connections Best practice is to fit an additional connector to the Socket 1 or use it only when it is impossible to program the controller via DATA0 and GND terminals Both Z 5R and Matrix II K controllers have a symmetric service pin connector for adapter connection via Socket 1 The Figure shows how to connect a Z 5R controller to this adapter Connection is p...

Страница 5: ...ls Terminals with the same name are internally joined within the adapter and allow connection to any of them The reader can be powered by the adapter if its maximum consumption current does not exceed 150 mA The adapter also automatically detects reader connection protocol iButton or Wiegand whose bit width is auto detected too Information about successfully acquired codes is transmitted into a CO...

Страница 6: ...sults are the same the code is deemed to be successfully acquired If corresponding signals are connected to the adapter as per the Figure below it becomes possible to manage the reader audial and visual indication by COM port commands as per p 4 above All indication control signals have 5 V level When reader power is connected to POWER terminal it becomes possible to turn it on and off by the COM ...

Страница 7: ...nections via a virtual COM port or when working on a remote terminal Also this method enables converting any external card reader into a desktop based one Note The described below features are additional and full operational compatibility with other devices is not guaranteed For example under control of external software the adapter can emulate a reader connected via iButton or Wiegand This allows...

Страница 8: ...in absence of precipitation direct sunlight sand dust water condensation This device is covered by a limited warranty for 24 months from the date of sale The warranty becomes void if This Manual is not followed Device has physical damage Device has visible traces of exposure to moisture and aggressive chemicals Device circuits have visible traces of being tampered with by unauthorised parties Unde...

Страница 9: ...ited 34 Ely Place London EC1N 6TD UK E mail marketing rfenabled com AVS LLC 7 Bobruiskaya street Saint Petersburg 195009 Russian Federation E mail marketing rfenabled com Phone 78122411853 78125421185 www ironlogic ru SIA IRONLOGIC 79A Slokas iela LV 1007 Riga Latvia E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me ...

Отзывы: