20
3
Press P9 to select the DEFROST cycle
4
The DL5 LED flashes
5
Open the door of the Blast chiller
6
Press P5
The DL5 and DL9 LEDS turn on
On DS1 the cell temperature is displayed
On DS2 the duration of the defrost cycle is displayed
in h:mm, where “h” represents the hours and “mm”
the minutes left until the end of the cycle.
7
Press P6 or P7 to increase or decrease
the time displayed on DS2.
The time is memorised 3s after the pressing of the
last button.
A product preservation cycle starts
ATTENTION! Do not use the Blast chiller
as a Conserver.
11M
Press P5 to interrupt preservation.
The Blast chiller goes back to “OFF”.
12M
Open the door of the Blast chiller, take the trays
out with the blast chilled food and put them back
in a Conserver.
13M
Defrost cycle selection and start-up
Description
Phase
1
The display shows:
• Internal chamber temperature
• Blast chiller "OFF" status
2
The DL1, DL2, DL3, DL4 LEDs flash waiting for
selection of the cycle
Front panel screen
Description
Phase
Front panel screen
When the set time is reached, the cycle ends.
An acoustic signal goes off for 5 seconds.
DS1 and DS2 flash.
10M
8
If the door closes during the DEFROST cycle:
• The cycle is suspended
• The remaining time counter blocks
• An acoustic signal goes off
• The “door” symbol flashes
Содержание EasyFresh
Страница 7: ...7 2 3 DIMENSIONAL DATA FRONT VIEW SIDE VIEW TOP VIEW EF10 1 EF20 1 EF30 1 EF45 1...
Страница 35: ......