5: APPENDICES
40
Iridium Pilot Land Station Installation Guide
Figure 18.
A
B
BDE RJ45 CONNECTOR WITH BOOT
ADE BUCCANEER PX0728/S CONNECTOR
SEE APPROVED CABLE LENGTH TABLE FOR LENGTH, PART AND MODEL NUMBERS
RJ45 CONNECTOR BAGGED SEPARATELY
XXXXXXXX
BAG LABEL
POLY-BAG
PINOUT TABLE
C
DETAIL A SCALE 2 : 5
CABLE PRODUCT LABEL
ADE BUCCANEER PX0728/S CONNECTOR
DETAIL B SCALE 2 : 5
CABLE
BOOT
RJ45 CONNECTOR
CABLE PRODUCT LABEL
DETAIL C SCALE 1 : 2
NOTES:
CABLE SPECIFICATIONS:
1. ∙ CABLE STOCK SHALL BE MARINE/OFFSHORE GRADE COLOR B
LACK (UV STABILIZED/RESISTANT), CATEGORY 5e
(OR BETTER) CABLE - TO IEC 332-1. ∙ CABLE TEMPERATURE RANGE FOR INSTALLATION AND OPERA
TION: -40°C TO +85°C.
∙ SHALL HAVE TWO (2) OR MORE SHIELDS: ONE (1) OR MOR
E BRAIDED TINNED COPPER AND ONE (1) FOIL
∙ SHALL HAVE A DRAIN WIRE AND HAVE ELECTRICAL CONTIN
UITY BETWEEN ALL SHIELDS AND DRAIN WIRE
∙ CABLE SHOULD HAVE STRANDED CONDUCTORS ∙ CABLE SHALL BE ROBUSTLY TERMINATED AT BOTHS ENDS W
ITH CONNECTORS
∙ CABLE SHOULD HAVE AT LEAST 2 INCH (50mm) BEND RADI
US FLEXIBILITY
ADE CONNECTOR PLUG BULGIN BUCCANEER PX0728/S, ASSEMBLED IN ACC
ORDANCE WITH THE CRIMP TOOL AND TORQUES
2.
SPECIFIED IN THE "STANDARD BUCCANEER" SECTION OF THE MANUFACTUR
ER'S CATALOG AND CONNECTED AS PER PINOUT TABLE
SHOWN ON ADE CONNECTOR COLUMN. BDE CONNECTOR PLUG TO BE: RJ45 TYPE SHIELDED PLUG (8-WAY, 8-POS
ITION) WITH BOOT, CONNECTED AS PER PINOUT TABLE SHOWN
3.
ON BDE CONNECTOR COLUMN; SUPPLY CABLE WITH TWO RJ45 PLUGS: ONE
FITTED TO THE CABLE, AS SHOWN AND ONE SUPPLIED AS KIT
FOR PARTS (BAGGED) TO FIT TO CABLE IF CUT TO LENGTH DURING INST
ALLATION.
PACKAGING FORM OF SUPPLIED CABLE TO BE:
4. ∙ COILED, TIE-WRAPPED AND POLY-BAGGED. ∙ INCLUDE A LEAFLET IN THE BAG THAT SPECIFIES THE F
OLLOWING:
- "THE MAXIMUM PERMITED LENGTH FOR THIS CABLE IS 50 METERS"
∙ THE BAG LABEL SHALL BE COMPLIANT WITH OP-035, AFF
IXED NEAR THE CENTER OF THE BAG AND BAG SEALED.
CABLE PRODUCT LABEL SHALL BE COMPLIANT WITH OP-062 AND AFFIXED
NEAR CONNECTOR AT EACH END.
5.
REVISIONS
REV.
DESCRIPTION
DATE
APPROVED
A
Released for production.
5/29/2013
SM
B
Added extra RJ45 BDE connector.
8/06/2013
SM
C
Added mfg. label and cable temperature range.
8/27/2013
SM
D
Added cable length table and erase note 4, added note 5.
10/04/2013
SM
E
Changed note 4, removed pinout table leaflet.
1/9/2014
SM
ADE CONNECTOR
CONDUCTOR COLOR
Standard (T568A)
BDE CONNECTOR
1
White/Orange stripe
3
2
Orange solid
6
3
Brown solid
8
4
Drain Wire
SHIELD
5
White/Brown stripe
7
6
Green solid
2
7
White/Green stripe
1
8
Blue solid
4
9
White/Blue stripe
5
APPROVED CABLE ASSEMBLY LENGTH
LENGTH
ITEM #
MODEL #
50m
115-00020
B50M1301
30m
115-00028
B30M1301
20m
115-00021
B20M1301
10m
115-00025
B10M1301
m=meters
D
E
F
C
1
2
3
4
B
A
3
2
1
5
C
D
4
6
7
8
A
B
5
6
7
8
E
E
E
1:5
1/10/2014
UNITS
mm
MATERIAL
- SEE NOTES-
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN IS THE PROPER
TY OF IRIDIUM SATELLITE
LLC AND/OR ITS AFFILIATES AND LICENSORS, UNLESS OTHERWISE STATE
D. NEITHER THIS DRAWING
NOR ANY SUCH INFORMATION MAY BE COPIED, REPRODUCED, TRANSMITTED
, DISTRIBUTED OR
OTHERWISE USED EXCEPT AS EXPRESSLY APPROVED IN WRITING BY IRIDI
UM SATELLITE LLC AND/OR
ITS AFFILIATES. NO RIGHTS OR LICENSES OF ANY KIND TO SUCH DRAWI
NG OR INFORMATION
(INCLUDING ANY INTELLECTUAL PROPERTY RIGHTS THEREIN) ARE TRANSF
ERRED TO, GRANTED TO,
PROVIDED TO OR RECEIVED BY THE RECIPIENT HEREOF AS A RESULT OF
THE DELIVERY HEREOF. THIS
MATERIAL MAY NOT IN WHOLE OR IN PART BE COPIED, STORED ELECTRON
ICALLY OR
COMMUNICATED TO THIRD PARTIES WITHOUT THE PRIOR WRITTEN AGREEME
NT OF IRIDIUM.
PROPRIETARY AND CONFIDENTIAL
GEOMETRIC TOLERANCING PER ASME Y14.5m-1994
3D REFERENCE
115-00020
DOCUMENT NUMBER
115-00020_E
DESCRIPTION:
ETHERNET CABLE SHIELDED Cat 5e WITH IP68 PANEL CONNECTOR & RJ45 PLUG- 50m
ISSUE DATE
SIZE
A3
REVISION
SCALE
SHEET
1 of 1
DRAWN BY
E. Vulcu
TOLERANCES: UNLESS OTHERWISE SPECIFIED
LINEAR DIMENSIONS ±0.15 ANGULAR DIMENSIONS ± 2° HOLE TO HOLE ±0.10
THIRD ANGLE PROJECTION
REVIEWED BY
S. Mallonee
Содержание Pilot TPIM1301
Страница 5: ...iv Iridium Pilot Land Station Installation Guide...
Страница 11: ...1 INTRODUCTION 6 Iridium Pilot Land Station Installation Guide...
Страница 29: ...2 INSTALLATION 24 Iridium Pilot Land Station Installation Guide...
Страница 33: ...3 NETWORK CONFIGURATION 28 Iridium Pilot Land Station Installation Guide...
Страница 40: ...5 APPENDICES Iridium Pilot Land Station Installation Guide 35...
Страница 53: ...48 Iridium Pilot Land Station Installation Guide 5 APPENDICES 83965_InstallGuide indd 44 3 2 12 8 01 AM...
Страница 55: ...5 APPENDICES 50 Iridium Pilot Land Station Installation Guide...
Страница 69: ...5 APPENDICES 64 Iridium Pilot Land Station Installation Guide...