IMPORTER

B&K LUMITEC

 

ZI  –  2 Rue Alfred Kastler – 67850 Herrlisheim – France

www.bklumitec.com

Содержание 113777

Страница 1: ...iridium Stage Profile Product Code 113777 ...

Страница 2: ...2 ...

Страница 3: ...fety instructions Proper Use Care 3 Description Products features Overview 4 Installation Overhead rigging DMX512 connection Power Input 5 Operation Control board DMX modes 6 Replacing the fuse 7 Focus 8 Technical specification 3 ...

Страница 4: ...ation regulations applicable at your location Make sure that the cables and plugs are not subject to tension or torsional forces and do not bend the cables Protect all cables and insulation against possible damages Output lines should be laid separately and spaced apart from other lines The power supply cables and the lamp feeders must not cross each other Do not allow the product to come into con...

Страница 5: ...t be constructed in a way that no part of the installation can fall down if the main attachment fails The operator has to make sure that safety relating and machine technical installations are approved by an expert and before taking into operation for the first time and after changes Please note for overhead rigging in public or industrial areas a series of safety instructions have to be followed ...

Страница 6: ...ry default Temperature C 000 0 255 Current temperature T 080 Protecting temperature Use Up and Down button to select your desired operation press Enter to set all function Notes When there s a flickering sign appeared means no signal input for the fixture No operation within 30seconds LCD display will enter into Screen protection mode automatic When the current temperature is higher than the prote...

Страница 7: ...ce the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Procedure Step1 Unscrew the fuse holder on the rear panel with a fitting screwdriver from the housing anticlockwise Step 2 Remove the old fuse from the fuse holder Step 3 Install the new fuse in the fuse holder Step 4 Replace the fuse holder in the housing and fix it 7 Focus The objective lens cylinder is usu...

Страница 8: ...imaging glass optical lens Color temperature 3200K CRI 90 Beam Angle 19 Dimming Range 16bit smooth dimming 0 100 DMX Channel 1CH 2CH 3CH Optional Control system STM32 control chip DMX512 signal Display Screen 4 Button LCD Screen IP Rating IP20 Min Distance to Illuminated object 1M Ambient Temp 15 C 35 C Product size 538x270x427mm Weight 10kgs Packing 1pc per carton Packing size 665x330x360mm 8 ...

Страница 9: ......

Страница 10: ...IMPORTER B K LUMITEC ZI 2 Rue Alfred Kastler 67850 Herrlisheim France www bklumitec com ...

Отзывы: