DMX Modes
DMX512 Channel table
1 Channel Table
Channel
Value
Rate
Function
CH1
Dimmer
0-255
Dimmer, brightness from 0%
2 Channel Table
Channel
Value
Rate
Function
CH1
Dimmer
0-255
Dimmer, brightness from 0%
CH2
DimmerFine
0-255
Brightness micro adjustment
3 Channel Table
Channel
Value
Rate
Function
CH1
Dimmer
0-255
Dimmable,brightness from 0%
CH2
DimmerFine
0-255
Brightness micro adjustment
CH3
Strobe
0-255
0-10 Strobe off, 11-255 Strobe frequency(from
slow to fast)
6. Fuse Replacement
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating. Before replacing the
fuse, unplug mains lead.
Procedure:
Step1: Unscrew the fuse holder on the rear panel with a fitting screwdriver from the housing (anticlockwise).
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing and fix it.
7. Focus
The objective lens cylinder is usually shrinked before leaving factory, after connect the projector to the mains, user may
loose the screws and pull out the lens cylinder, till the white light output circular is clearly presented, locking tightly the
two screws again.
When the projection distance is changed, user can follow previous operating steps, and focus the projector.
7