Select the
Pixels Defect Calibration
option with the
Z (5) / C
(3)
button in the
More
submenu.
➢
Briefly press of the
M (4)
button to enter the pixels defect
calibration interface.
➢
A small cross cursor instead of the reticle will appear on the
center of the screen.
➢
The Picture in Picture (PIP) window will appear on the lower left corner of the screen. A tooltip is appeared
on the bottom of the screen that displays the number of the blind pixels calibrated, the movement direction
and location.
➢
Move the cursor to align with the defective pixel with a short or long press the
Z (5) / C (3)
button. Short
press to move one pixel every time and long press to move ten pixels once.
➢
Switch the movement direction with a short press of the
M (4)
button.
➢
After selecting the blind pixel, long press
Z (5) + C (3)
button to calibrate the defective pixel, and press the
same button again for cancelation.
➢
Repeat the above processes until all blind pixels are calibrated.
➢
Press and hold the
M (4)
button to save the calibration and exit to the
More
submenu.