If you do not have professional equipment for calibration, find a building 100m away with a great distance
between the front and rear (such as a large building in open areas).
➢
Move the device slowly from left to right so that the building appears in the eyepiece gradually. In the
meantime, observe the rangefinder data in the upper right corner. When finding the critical point of the
rangefinder data changing, such as the point changing from
—
m to the measured number, press the
Z (5)
/ C (3)
button to move the rangefinder cursor left / right to the boundary between the building and the
background to complete the calibration of the left and right positions.
➢
Use the same operation above to complete the calibration of the
up and down positions.
➢
Briefly press of the
M (5)
button to switch the movement
direction of the cursor.
➢
After calibration, press and hold down the
M (5)
button to save
and exit to the More submenu.
Pixels Defect
Calibration
Calibrate the defective pixels
Defect pixels are pixels that do not change brightness compare with others on the image, they are either
brighter or darker than surrounding pixels. Geni series offer the possibility of removing any defective pixels
on the sensor using software, as well as to cancel any deletion.