background image

THIS PRODUCT IS A CLASS 3R LASER PRODUCT

 

Use of controls or adjustments or performance of procedures other than those specified 

herein may result in hazardous radiation exposure.

W A R N I N G !

ITAR REQUIREMENTS

These products may be subject to export and foreign trade control laws of  

the United States and may not be exported without prior approval of the  

U.S. Department of State. Learn more at irayusa.com/ITAR.

TABLE OF CONTENTS 

1.   OVERVIEW 

1

2.   FEATURES 

1

3.   PACKAGE  CONTENTS 

1

4.  TECH SPECIFICATIONS 

2

5.   UNITS AND CONTROLS 

3

6.   BATTERY AND SAFETY 

5

7.   EXTERNAL POWER SUPPLY 

7

8.   INSTALLATION AND USE 

7

9.   CALIBRATION 

8

10. DIGITAL ZOOM 

9

11. PHOTOGRAPHING AND VIDEO RECORDING  9
12. STATUS BAR OVERVIEW 

11

13. SHORTCUT MENU 

11 

14. MAIN MENU 

12

  

 ULTRACLEAR 

12

     WI-FI 

13

      VIDEO OUTPUT 

13

     CALIBRATION 

13 

      DIGITAL COMPASS 

13

      GRAVITY SENSOR 

14

      LASER CURSOR CALIBRATION 

14

      PIXEL DEFECT CORRECTION 

15

      COMPASS CALIBRATION 

15

     STANDBY 16
      IMAGE HUE 

16

     SETTINGS 

16

      

DATE 16

     TIME 

16

     LANGUAGE 

17

        STATUS AUTO HIDING 

17

     FACTORY 

RESET 

17 

     INFO 

18

15. PICTURE IN PICTURE (PIP) 

19

16. LASER INDICATOR  

19

17. STADIAMETRIC RANGEFINDING 

19

18. LED LIGHT 

20

19. HOTSPOT TRACKING  

21

20. AUTOMATIC HIDING  

21

21. WI-FI FUNCTION 

22

22. BASIC INSPECTION/MAINTENANCE  

23

23. WARRANTY 

23

24.

 

FCC INFORMATION 

24 

25. GENERAL TROUBLESHOOTING  

25

iRayUSA 800 Railhead Road #316 Fort Worth TX 76106

800.769.7125 [email protected] 

This Laser Product is designated as Class 3R during all procedures of operation.

Wavelength: 635nm

Laser Power for classification: <5mW (4mW typical)

Emission Type: CW

Beam Diameter: <3mm at aperture

Divergence: <1mRad

LASER LIGHT

AVOID DIRECT EYE EXPOSURE

CLASS 3R LASER PRODUCT

 

     

NOTES

There is no scheduled maintenance or service necessary to keep this product in 

compliance and no user service or maintenance is required. 

This product is to be serviced or repaired only by factory authorized technicians.

This product is not to be opened or modified by the user, nor is it allowed to attempt to 

cheat or defeat safety interlocks. 

The user is not to modify the unit or remove protective covers or housing. Service is 

only to be handled by authorized factory trained technicians. This product has no user 

serviceable parts.

Do not point laser or allow laser light to be directed or reflected toward other people or 

reflective objects. 

Operators should be trained to not target the eyes of people, animals and pets or aim 

at reflective objects etc.

There is a potential hazard of eye or skin exposure to laser radiation if the included 

instructions are not followed.

This laser is never to be operated if the unit is defective or the cover or seal is damaged.

Always operate the CABIN Series with the aperture pointed downrange.

CAUTION

Mfr. ID and Certification Label

Explanatory Label

Laser Aperture

Содержание Cabin Series

Страница 1: ...I N F I R A Y O U T D O O R CABIN SERIES T h e r m a l I m a g i n g M o n o c u l a r User s Manual Outdoor...

Страница 2: ...SHOOTING 25 iRayUSA 800 Railhead Road 316 Fort Worth TX 76106 800 769 7125 info irayusa com This Laser Product is designated as Class 3R during all procedures of operation Wavelength 635nm Laser Power...

Страница 3: ...4 F 122 F 4 TECH SPECIFICATIONS 1 OVERVIEW The InfiRay Outdoor Cabin Series is a compact and powerful optic that operates easily with one hand The CABIN is available with multiple lens options and it...

Страница 4: ...ON OFF Shortcut Menu Main menu Navigation Up Laser Cursor Calibration Defective Pixel Calibration Interface Move Cursor Left Quickly Move Cursor Left Down Photo Home Screen Capture Image Turn Recordin...

Страница 5: ...fter you bring it from a cold area to a warm area Wait 30 to 40 minutes for the battery to warm up Do not use the charger if it is modified or damaged The device should be charged at a temperature of...

Страница 6: ...he countdown counts from 3 to 0 the device is now shut down The current user selections will be automatically saved after shutdown During the shutdown period do not remove the battery or these selecti...

Страница 7: ...day in memory The photography images and recorded videos of each individual day are stored in these folders You can copy or delete the required files or folders 10 DIGITAL ZOOM The CABIN Series featur...

Страница 8: ...m 1 dim to 5 bright Image Sharpness After selecting this option press the 12 STATUS BAR OVERVIEW Menu Button 7 to adjust the Image Sharpness from 1 lowest sharpness to 5 highest sharpness Image Contra...

Страница 9: ...press the Menu Button 7 After moving the cursor to the location indicated by the laser press and hold the Menu Button 7 to save the location and return to the home screen WI FI Turn Wi Fi on off Pres...

Страница 10: ...tton 7 to access the Menu short press the Up Zoom Button 6 or Down Photo Button 8 until you select the Compass Calibration Short press the Menu Button 7 to enter Compass Calibration The calibration ic...

Страница 11: ...Button 8 to select YES or NO YES will restore factory settings and NO will cancel the operation Short press the Menu Button 7 to confirm the selection If YES is selected the device will shut down aut...

Страница 12: ...it 8 as well as their distance values in meters To change the unit of measure between meter and yards short press the Menu Button 7 Adjust these measurement lines to match the height of your target by...

Страница 13: ...nits serial number Select the appropriate Wi Fi option and enter the password The initial password is 12345678 After Wi Fi is accessed you can control the device via the mobile App Setting Wi Fi Name...

Страница 14: ...any warranty coverage Any serial number damage or alteration on the product will be considered modification Please give us a call at 800 769 7125 visit irayusa com warranty email Info InfiRayUSA com w...

Страница 15: ...i networks or to an area without Wi Fi coverage The image of the object being observed is missing Looking through glass Remove any glass windows from the field of view The image quality or contrast is...

Страница 16: ...27 28 NOTES...

Страница 17: ...29 30 NOTES...

Страница 18: ...ct to change without notice For the most up to date specs go to irayusa com Not responsible for typographical errors Ver 1 10102721 800 Railhead Road 316 Fort Worth Tx 76106 800 769 7125 682 499 0047...

Отзывы: