www.irrobot.com
35
1) Test the workability of the air blower by pushing the blow button on the control panel.
2) The ball is still not come out :
If there is any elements, particles, or dusts in the goal area or in the guide, the ball will
not come out to the ground and it needs to remove them immediately.
3) How to remove particles : Use the vacuum cleaner to remove particles in the ground
especially in the goal area and remove particles in the ball guide pipe.
6.3 The ball does not come out.
Once the ball goes into goal area, the ball move through the guide to the
center pipe and Air Blow System will blow out the ball to the playground.
In case of free mode, the ball is not come out automatically after the game
over. Both start buttons should be pushed to make the ball out.
The balls might be jammed at the entrance.
(Ball guide pipe)
Push the blow button
on the control panel.
6.2.3 The Robot do not go straight
1) Check 6 power supplying pins on the bottom of the robot whether all pins are in the
same height and same tension by pushing the pin one by one.
Disordered supplying pin effects in motion of a robot and replace supplying pins
that don't push it easily.
2) Check the motions of robot's wheels and tires. If it is worn out, replace it according to
page 34