Electrical specifications
Typical values
unless otherwise stated
Supply voltage
5.0 V supplied from USB
USB
V2.0 Compliant SIE
TR transceiver
TR-72D compatible, without temperature sensor
Supply current
About 15 mA (TR not transmitting), 50 mA max. (TR transmitting)
RF band
868 MHz or 916 MHz
3
(software configurable)
RF channels
See IQRF OS User’s guide, Appendix
Channel maps
RF data modulation
GFSK (Gaussian Frequency Shift Keying)
RF data transmission bit rate
1
19.836 kb/s
RF IC RF sensitivity
-106 dBm (STD RX mode,
checkRF(0)
)
RF IC RF output power
11 dBm, programmable in 8 levels (0
– 7)
RF range
2
500 m
Antenna
Built in PCB
Operating temperature
0 °C to +70 °C
Dimensions
59.3 mm x 23.5 mm x 12.3 mm (including the cover)
Weight
12 g (including the cover)
Note 1:
Several RF bit rates different from 19.836 kb/s will be available in future IQRF OS versions.
Note 2:
Arrangement:
Two GW-GSM-06 devices plugged via USB cables, in vertical positions, 1.6 m above the ground, in free space.
The range is significantly shortened when the GW is plugged directly in a USB device.
The range is significantly shortened in direction of longitudinal axis (the GW placed in horizontal position).
Test software:
E09-LINK
example (STD mode,
setRFpower(7)
,
checkRF(0)
)
,
bit rate 19.836 kb/s.
Note 3:
916 MHz band is available from IQRF OS v3.08D.
Absolute maximum ratings
Stresses above listed maximum values may cause permanent damage to the device and affect device reliability. Functional
operation at these or any other conditions beyond those specified is not supported.
Supply voltage (V
CC
)
5.5 V
Storage temperature
-2
0 °C to +70 °C
Caution:
Electrostatic sensitive device. Observe appropriate precautions for handling.
Information contained in this publication regarding device applications and the like is provided only for your convenience and may be
superseded by updates. It is your responsibility to ensure that your application meets with your specifications.
MICRORISC MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND TO STATED CONDITION, QUALITY,
PERFORMANCE, MERCHANTABILITY OR FITNESS FOR PURPOSE and disclaims all liability arising from this information and its use.
Use of MICRORISC devices in life support and/or safety applications is entirely at the buyer’s risk, and the buyer agrees to defend,
indemnify and hold harmless MICRORISC from any and all damages, claims, suits, or expenses resulting from such use. No licenses