IQAir GCX series Скачать руководство пользователя страница 9

9

Chapter 4

– Using the Control Panel

4.1.1  Description of Control Panel Keys

Power Key

The 

Power

key switches the IQAir® system on and off.  When the system is switched off, the fan stops to run, but the

system will remain connected to the power supply (standby mode). The standby mode allows for automatic timer
start-up. In the standby mode, the different menu functions can be accessed. 

Tip: 

In a menu window,    the 

Power

key also serves as a quick exit key to return to the main display window.

Arrow (

) Key

When the system is switched on, the 

key allows the adjustment of the fan speed. In the enter mode, indicated by

the appearance of a black flashing cursor (see “Enter Key” below), the 

key is used to modify the selected setting in

the display window. Confirmed with the 

Enter

key, the enter mode is automatically terminated. The LCD will then

display the current menu settings for another 15 seconds before reverting to the main window display.

Chapter  4  –  Using the Control Panel

The IQAir® system is operated and controlled via the electronic control panel which is located at the top of the front
locking arm.

Several operations can be completed via the electronic control panel:

Switching the system on and off

Controlling the fan speed and corresponding air delivery rate

Checking the remaining filter life of the individual filters

Setting the automatic timer

Resetting the Filter Life Monitor after replacing a filter

Locking the control panel to avoid tampering with the system’s settings

Choosing the desired display language

Setting the day & time

4.1 Description of Control Panel

LCD 

= Liquid

Crystal Display

Power

Key

Enter

Key

Menu

Key

Arrow

Key

Post-Filter Life LED

Cartridges Life LED

Pre-Filter Life LED

Timer LED

Fan Speed LEDs

LCD Display

The 2-line LCD displays important information about the system’s settings.

In standby mode, without the timer activated, the first line displays IQAir GCX
and the second line displays Standby. If the timer is activated, the first line
displays the day and time and the programmed start and stop times will be
displayed on the second line.

If the IQAir® system is on, the first line displays the current speed set ting and the
second line displays the corresponding air delivery rate of the system; however,
when the timer is activated the programmed start and stop times will be
displayed on the second line.

By pressing the Menu key, ten active menu functions may be accessed. These
functions are explained in detail in this chapter.

LED 

= Light Emitting Diode

Main window: Standby mode

Main window: On mode

Menu window: Filter Life Monitor

Pre-Filter

Cartridges

Post-Filter

Содержание GCX series

Страница 1: ...G C X S e r i e s High Performance Air Cleaning System User s Manual Swiss Made...

Страница 2: ...and similar appliances Only use this appliance for its intended purpose of air cleaning in non industrial environments Do not use this appliance in areas with very high concentrations of dusts or powd...

Страница 3: ...eek Timer 14 4 4 5 Timer ON OFF Fan Speed Selection Menu 14 4 4 6 Timer Information in the Control Panel 15 4 4 7 Time Day Setting 16 4 4 8 Filter Life Reset 16 4 4 9 Changing Airflow Units 17 4 4 10...

Страница 4: ...able to reverse the conversion of oxygen O2 into carbon dioxide CO2 caused by breathing and combustion processes 3 Ensure the IQAir system can clean enough air to cope with your room size The actual...

Страница 5: ...rtificate of Performance Referral Program I certify that the above information is correct Referrer s Signature The IQAir Referral Program Shell no Serial no Last name First name Company name Phone Add...

Страница 6: ...surface such as a wall or a cupboard In general the more centrally the system is positioned the better the performance Position the system close to a power outlet and make sure that the power cord is...

Страница 7: ...ffuser is designed for carrying the IQAir system The EvenFlow Diffuser features an omni directional horizontal air outlet Frame 3 to 5 surrounds the 4 gas phase cartridges and filter sleeves to where...

Страница 8: ...articulate post filter sleeves hold back abrasion particles from the gas phase filter media 6 Low turbulence low velocity air is returned to the room via the EvenFlow diffuser 3 2 Description of Remov...

Страница 9: ...trolling the fan speed and corresponding air delivery rate Checking the remaining filter life of the individual filters Setting the automatic timer Resetting the Filter Life Monitor after replacing a...

Страница 10: ...ction in airflow particle filters are clogged or a reduction in filter efficiency gas phase filter is saturated Fan Speed LEDs These LEDs simulate the fan speed through the frequency of their rotation...

Страница 11: ...f the IQAir system cfm x 60 air changes per hour ACH air volume of the room cu ft L x W x H Note The air delivery rates of the IQAir system at the various fan speeds settings are listed on the Technic...

Страница 12: ...g How the Filter Life Monitor Works The basis for the calculation of the remaining filter life is the already elapsed operation time at the set fan speed This input is compared with an internal memory...

Страница 13: ...u key twice 2 Press and hold the Enter key until the cursor starts to flash 3 Press the key once to activate the timer Note If the start and stop time are identical the timer cannot be activated 4 Pre...

Страница 14: ...n and exits the enter mode 4 4 4 Day of the Week Timer The Day of the Week Timer allows the deactivation of the Timer ON period on certain days of the week In its default setting the Timer ON period i...

Страница 15: ...first line shows the fan speed and the second line shows the airflow The Timer LED is off System on Standby The first line shows the current day and time and the second line shows the next time the sy...

Страница 16: ...window press the Enter key Note If the wrong filter has been selected or if you wish to exit the enter mode press the Menu key This leaves the Filter Life unchanged 6 Upon successful reset of the filt...

Страница 17: ...e Control Panel 4 4 9 Changing the Airflow Units 1 To reach the air flow units menu from the main display window press the menu key eight times The current airflow unit is displayed 2 You can change t...

Страница 18: ...press the OFF key Switching the Timer On and Off If start and stop times have been set in the Daily Timer Menu it is possible to switch the timer on and off with the remote control To switch the timer...

Страница 19: ...Control When the battery becomes weak the transmission results will deteriorate and the battery should be replaced The remote control requires one CR2025 battery The battery compartment is located at...

Страница 20: ...imply push the locking arms inwards simultaneously until they snap back into the housing IQ Air 20 Chapter 6 Replacing Filters Opening Closing 6 3 1 Troubleshooting when Closing the Housing If the IQA...

Страница 21: ...the frame and push them down If known harmful substances are filtered please refer to local regulations or laws for proper filter disposal 6 5 Replacing the Gas Phase Filter Filter 2 and Post Filter...

Страница 22: ...ing or after the warranty period please contact your point of purchase or call IQAir Technical Support at 888 560 1020 toll free or email support iqair com To expedite your service request please have...

Страница 23: ...fety Screws The only additional tool you need to enable the anti tampering features is a medium size flat head screw driver How to install the power cable fixture 1 Make sure the power cord is unplugg...

Страница 24: ...tighten using the supplied tool 7 8 6 9 Plug the red connector of the ribbon cable back into the control panel Ensure that it is pushed in all the way 10 Reinsert the control panel and press it in com...

Страница 25: ...side the room OutFlow Complete ducting adapter kit for the creation of negative pressure if placed within the room and positive pressure if placed outside the room PF40 Additional pre filter for areas...

Страница 26: ...26 Notes...

Страница 27: ...27 Notes...

Страница 28: ...090304_IQ_MA_GC_US www iqair com Swiss Made...

Отзывы: