2.2 Choosing a Suitable Location

When choosing a suitable location for the
IQAir system, keep the following considerations
in mind:

Choosing the most suitable room for the
system will depend on where you would
like the focus of the air cleaning efforts. Two
main considerations are the time you spend
in a particular room and the location of the
main air pollution sources. As a general rule,
the closer the system is located to the air
pollution source, the better the air cleaning
performance in the room.  
Although an air cleaning result may be
achieved in adjacent rooms, the main air
cleaning will take place in the room where
the system is located. For the best air
cleaning results in adjacent rooms, make
sure that doors to these rooms are left wide
open.

For best performance, the system should be positioned at least 12 inches (1 foot) away from the nearest vertical
surface, such as a wall or a cupboard. In general, the more centrally the system is positioned, the better the
performance.

Position the system close to a power outlet and make sure that the power cord is positioned in a way that it does
not present an obstacle.

Make sure that the system is positioned in such a way that the control panel is easily accessible.

2.3  Connecting to Power

1.  Plug the connector end of the power cord into the recessed power inlet socket on the back of the system.
2. Plug the other end of the power cord into a power outlet or power strip.

Important: 

The only way to disconnect power completely is to unplug the power cord. 

Do not use the IQAir® system when the power cord becomes damaged. 

The power cord may be replaced with an

approved cord with a two-pole plug. These power cords are commonly used for computers and similar appliances. 

6

Chapter 2

– Setting Up

Power outlet

Power cord plug
(plug types vary)

Power cord connector

Power inlet socket

min. distance
12” (1 foot)

Control panel should
be easily accessible

Keep power cord
clear of walk-ways

Содержание GCX series

Страница 1: ...G C X S e r i e s High Performance Air Cleaning System User s Manual Swiss Made...

Страница 2: ...and similar appliances Only use this appliance for its intended purpose of air cleaning in non industrial environments Do not use this appliance in areas with very high concentrations of dusts or powd...

Страница 3: ...eek Timer 14 4 4 5 Timer ON OFF Fan Speed Selection Menu 14 4 4 6 Timer Information in the Control Panel 15 4 4 7 Time Day Setting 16 4 4 8 Filter Life Reset 16 4 4 9 Changing Airflow Units 17 4 4 10...

Страница 4: ...able to reverse the conversion of oxygen O2 into carbon dioxide CO2 caused by breathing and combustion processes 3 Ensure the IQAir system can clean enough air to cope with your room size The actual...

Страница 5: ...rtificate of Performance Referral Program I certify that the above information is correct Referrer s Signature The IQAir Referral Program Shell no Serial no Last name First name Company name Phone Add...

Страница 6: ...surface such as a wall or a cupboard In general the more centrally the system is positioned the better the performance Position the system close to a power outlet and make sure that the power cord is...

Страница 7: ...ffuser is designed for carrying the IQAir system The EvenFlow Diffuser features an omni directional horizontal air outlet Frame 3 to 5 surrounds the 4 gas phase cartridges and filter sleeves to where...

Страница 8: ...articulate post filter sleeves hold back abrasion particles from the gas phase filter media 6 Low turbulence low velocity air is returned to the room via the EvenFlow diffuser 3 2 Description of Remov...

Страница 9: ...trolling the fan speed and corresponding air delivery rate Checking the remaining filter life of the individual filters Setting the automatic timer Resetting the Filter Life Monitor after replacing a...

Страница 10: ...ction in airflow particle filters are clogged or a reduction in filter efficiency gas phase filter is saturated Fan Speed LEDs These LEDs simulate the fan speed through the frequency of their rotation...

Страница 11: ...f the IQAir system cfm x 60 air changes per hour ACH air volume of the room cu ft L x W x H Note The air delivery rates of the IQAir system at the various fan speeds settings are listed on the Technic...

Страница 12: ...g How the Filter Life Monitor Works The basis for the calculation of the remaining filter life is the already elapsed operation time at the set fan speed This input is compared with an internal memory...

Страница 13: ...u key twice 2 Press and hold the Enter key until the cursor starts to flash 3 Press the key once to activate the timer Note If the start and stop time are identical the timer cannot be activated 4 Pre...

Страница 14: ...n and exits the enter mode 4 4 4 Day of the Week Timer The Day of the Week Timer allows the deactivation of the Timer ON period on certain days of the week In its default setting the Timer ON period i...

Страница 15: ...first line shows the fan speed and the second line shows the airflow The Timer LED is off System on Standby The first line shows the current day and time and the second line shows the next time the sy...

Страница 16: ...window press the Enter key Note If the wrong filter has been selected or if you wish to exit the enter mode press the Menu key This leaves the Filter Life unchanged 6 Upon successful reset of the filt...

Страница 17: ...e Control Panel 4 4 9 Changing the Airflow Units 1 To reach the air flow units menu from the main display window press the menu key eight times The current airflow unit is displayed 2 You can change t...

Страница 18: ...press the OFF key Switching the Timer On and Off If start and stop times have been set in the Daily Timer Menu it is possible to switch the timer on and off with the remote control To switch the timer...

Страница 19: ...Control When the battery becomes weak the transmission results will deteriorate and the battery should be replaced The remote control requires one CR2025 battery The battery compartment is located at...

Страница 20: ...imply push the locking arms inwards simultaneously until they snap back into the housing IQ Air 20 Chapter 6 Replacing Filters Opening Closing 6 3 1 Troubleshooting when Closing the Housing If the IQA...

Страница 21: ...the frame and push them down If known harmful substances are filtered please refer to local regulations or laws for proper filter disposal 6 5 Replacing the Gas Phase Filter Filter 2 and Post Filter...

Страница 22: ...ing or after the warranty period please contact your point of purchase or call IQAir Technical Support at 888 560 1020 toll free or email support iqair com To expedite your service request please have...

Страница 23: ...fety Screws The only additional tool you need to enable the anti tampering features is a medium size flat head screw driver How to install the power cable fixture 1 Make sure the power cord is unplugg...

Страница 24: ...tighten using the supplied tool 7 8 6 9 Plug the red connector of the ribbon cable back into the control panel Ensure that it is pushed in all the way 10 Reinsert the control panel and press it in com...

Страница 25: ...side the room OutFlow Complete ducting adapter kit for the creation of negative pressure if placed within the room and positive pressure if placed outside the room PF40 Additional pre filter for areas...

Страница 26: ...26 Notes...

Страница 27: ...27 Notes...

Страница 28: ...090304_IQ_MA_GC_US www iqair com Swiss Made...

Отзывы: