SECTION THREE

INSTALLATION

After choosing a suitable location (see previous section) install the unit as follows:
The unit is suitable for connection to a 240 V ac 50Hz electricity supply. It is suggested that 
3-core round flexible cable of 1mm² gauge is used. An internal switch should be installed to
switch the power to the unit ON & OFF. This allows the sensor to be easily switched off when not
required or for maintenance purposes.

This product is designed to be mounted on walls or under eaves, see diagram E. The sensor can
be rotated through 180 degrees to direct detection where required, decide on your location before
installation.

Remove the unit from its packaging.  

Unscrew the wiring box fixing screw shown on diagram F. This screw is captive, do not fully
remove.

Detach the wiring box from the Sensor body.

Using the wall plate as a template, mark the position of the fitting holes.  
Drill the holes. Insert the wall plugs into the holes.

PIERCE & PASS THE CABLE(S) THROUGH THE GROMMET(S) BEFORE PROCEEDING.
It is recommended that the grommet is pierced with a screwdriver to ensure a better seal.

Attach the mounting plate to the wall using screws provided. Do not overtighten the mounting
screws as this could damage the unit.  If using a power screwdriver, use the lowest torque
setting.

This unit features an installation aid. Simply hang the Sensor onto the wall plate by use of the clip
arrangement on the wall plate. See diagram H. This allows you to use your hands to hold the
screwdriver, and install the incoming cables with ease.
Connect the incoming and outgoing cables as follows

*** IMPORTANT ***

Switch off the electricity at the fuse box by removing the relevant fuse or switching off

the circuit breaker before proceeding with the installation.

CONNECTION

Connect the 

mains supply cable

to the terminal block on the unit as follows (see connection

diagram): 

NEUTRAL (Blue)  

N      

EARTH (Green/Yellow) 
LIVE (Brown)  

L

Connect the 

cable from the lighting load(s)

to the terminal block on the unit as follows (see

connection diagram): 

Security Output

Courtesy Output

NEUTRAL (Blue)  

N      

NEUTRAL (Blue)  

N

EARTH (Green/Yellow) 

EARTH (Green/Yellow)

LIVE (Brown) 

L1

LIVE (Brown) 

L2

Ensure that all connections are secure.

SF-SA-180-D PIR HiLo 10A.qxd  16/05/2005  11:17  Page 4

Содержание E-808

Страница 1: ... PIR Motion Detector E 808 Version 2 02 05 IQ SA 180 D GR IQ Europe Limited Sandbeck Lane Wetherby LS22 7TW Visit us at www iq europe co uk Installation helpline 0871 717 1100 SF SA 180 D PIR HiLo 10A qxd 16 05 2005 11 17 Page 1 ...

Страница 2: ...nmental conditions If the buyer is resident in the EU the product or its replacement will be returned to the buyer at the expense of IQ This guarantee excludes liability for discolouration of paint or plastic or any user replaceable parts and in particular lamps glass panels or globes lanterns It does not confer any rights other than those expressly set out above and does not cover any claims for ...

Страница 3: ...ds to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimum height of 2 5m Careful positioning of the sensor will be required to ensure optimum performance See diagram A detailing detection range and direction The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS see diagram...

Страница 4: ...mmended that the grommet is pierced with a screwdriver to ensure a better seal Attach the mounting plate to the wall using screws provided Do not overtighten the mounting screws as this could damage the unit If using a power screwdriver use the lowest torque setting This unit features an installation aid Simply hang the Sensor onto the wall plate by use of the clip arrangement on the wall plate Se...

Страница 5: ...e trapped the lower edge of the unit will locate into the wallplate Fullly tighten the fixing screw See diagram F Installation is complete MANUAL OVERRIDE MODE The light can be switched on for longer time periods by use of the Manual Override Mode This can be activated at night by using the internal wall switch or circuit breaker Switch the internal wall switch circuit breaker off on off on within...

Страница 6: ...IEW 12m 2 5m A C Less sensitive More sensitive B D Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection Dusk Time DIM SF SA 180 D PIR HiLo 10A qxd 16 05 2005 11 17 Page 6 ...

Страница 7: ...SETTING UP FOR AUTOMATIC OPERATION When walk tests are complete the unit can be switched to automatic operation The TIME setting controls how long the unit remains illuminated following activation after all motion ceases The minimum time fully anti clockwise is approx 5 seconds whilst the maximum time fully clockwise is approx 5 minutes Set the control to the desired setting between these limits T...

Страница 8: ...ut 0 to 60 of maximum output 5 seconds 5 minutes Day night or night only operation IP44 suitable for outdoor use 12 months If you experience problems refer to Troubleshooting Guide If problems still exist do not immediately return the unit to store Telephone the IQ Customer Helpline 0871 71 71 100 Weekdays 9 00am 5 00pm support iq group com www iq europe co uk Qualified Customer Support Co ordinat...

Страница 9: ... and check the wiring connections Check the lamp If the lamp has failed replace Ensure that the lamp is seated correctly in the lampholder Please note that the unit will not detect through glass The level of ambient light in the area may be too bright to allow operation at the current DUSK setting During the hours of darkness adjust the DUSK control slowly clockwise until the lamp illuminates Refe...

Страница 10: ...E G Wall Mount Ceiling or eave mount 180 degree rotation of sensor head ensures accurate detection control Wiring Box fixing screw F SF SA 180 D PIR HiLo 10A qxd 16 05 2005 11 17 Page 10 ...

Страница 11: ...all plate for easier wiring Extra view shows detail of clip arrangement 1 Align top edge and click 2 Rotate sensor body down and click lower edge into place Fully tighten sensor fixing screw SF SA 180 D PIR HiLo 10A qxd 16 05 2005 11 17 Page 11 ...

Страница 12: ...nce over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a unit or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light spread on all halogen floodlights can be reduced by angling the floodlight downwards on the mounting bracket This will also concentrate the light...

Отзывы: