background image

SECTION ONE

GENERAL INFORMATION

The unit features an integral daylight sensing photocell which will automatically switch the light on
at dusk and off at dawn or at a time set by the user.

PARTS INCLUDED

- Luminaire c/w PIR Sensor unit
- Instruction manual. 

Please keep safe for future reference.

- Accessory Pack
- Wall mounting plate
- 13W PL Low Energy Lamp
Unit is for outdoor use only.  
Unit must be mounted as a fixed luminaire, and is not suitable for portable use.
The unit can get hot during use.  Ensure the unit has cooled before handling.
Do not attempt to install during wet weather, if you are suffering from nausea or dizzy spells or on
medication with similar side effects.

SECTION TWO

After choosing a suitable location (see previous section) install the unit as follows:
The unit is suitable for connection to a 240 V ac 50Hz electricity supply. It is suggested that 
3-core round flexible cable of 1mm² gauge is used. An internal switch should be installed to
switch the power to the unit ON & OFF. This allows the unit to be easily switched off when not
required or for maintenance purposes.

TOOLS & PARTS NEEDED

- 3 flexible core cable
- 240V 60W (max) GLS ES lamp or 23W 
CFL Energy Saving Lamp
- Electric/hand-held drill & bits
- Terminal or Electricians screwdriver
- Wire cutters

*** IMPORTANT ***

As of 1 January 2005, changes to the Building Regulations affect domestic electrical installations in

England and Wales. You don't need to be a qualified electrician to make changes to your home's electrical

system, but the work must be done in accordance with the Regulations. 

Where you employ an electrician who is a member of a competent person self-certification scheme, they

will be able to certify the work complies with the Regulations.

If you decide to carry out the work yourself we recommend that you make yourself aware of the

Regulations before you begin and if you require any clarification you should contact your Local Authority

Building Control Department.

Details of the Building Regulations can be obtained on the internet via the government website

www.odpm.gov.uk/explanatory-booklet 

INSTALLATION

Remove wall plate from the lantern as follows:-

Diagram B. Using a small flat blade terminal screwdriver so as not to damage the clip, carefully
prise the lower clip off its locating rib on the lantern bracket. The lower edge of the lantern bracket
will now be partially released

Diagram C. Rotate the lower edge of the lantern off the wall bracket and lift the lantern upwards
and away from the two locating lugs on the top of the wall bracket.

Diagram D. Using the back plate as a template drill the holes. Insert the rawl plugs into the holes. 

IQ-PCL-PH-13-6-B.qxp  14/12/2006  10:52  Page 3

Содержание E-294B

Страница 1: ... E 13W Low Energy Lantern E 294B Version 1 12 06 IQ PCL PH 13 6 IQ Europe Limited Sandbeck Lane Wetherby LS22 7TW Visit us at www iq europe co uk Installation helpline 0871 717 1100 IQ PCL PH 13 6 B qxp 14 12 2006 10 52 Page 1 ...

Страница 2: ...ility of the buyer to prove delivery to IQ The product has been bought by the user The product has not been misused or handled carelessly installed incorrectly or used on a voltage supply other than that shown on it Repairs have not been attempted by anyone other than IQ s staff The product has been used for domestic purposes only The product has not been installed in any unusually exposed or hars...

Страница 3: ...s screwdriver Wire cutters IMPORTANT As of 1 January 2005 changes to the Building Regulations affect domestic electrical installations in England and Wales You don t need to be a qualified electrician to make changes to your home s electrical system but the work must be done in accordance with the Regulations Where you employ an electrician who is a member of a competent person self certification ...

Страница 4: ...t to ease installation Simply turn the lantern as Diagram E and clip the lantern onto to the hook on the inside of the wall plate The lantern will now be restrained to aid cable connection CONNECTION Connect the cable to the terminal block on the unit as follows see connection diagram NEUTRAL Blue N EARTH Green Yellow LIVE Brown L Ensure that the connections are secure Ensure no wires are trapped ...

Страница 5: ...off baseplate to release lantern 2 C 1 1 Release lower edge of wall bracket from lantern 2 Lift lantern off wall bracket to release from locating pillars Locating holes and pillars IQ PCL PH 13 6 B qxp 14 12 2006 10 52 Page 5 ...

Страница 6: ... to carefully prise 2 x clips on underside of lantern lid to release this mark on the lid above clip location identifies the position of the clips to aid re assembly F D wall fixing holes cable inlet E IQ PCL PH 13 6 B qxp 14 12 2006 10 52 Page 6 ...

Страница 7: ...At this position the unit should become operative at approximately the same level of darkness each evening Observe the operation of the unit If the unit is starting to operate too early ie when it is quite light adjust the control slightly anti clockwise If the unit starts to operate too late ie only when it is very dark adjust the control slightly clockwise Continue to adjust until the unit opera...

Страница 8: ...eration at the current DUSK setting During the hours of darkness adjust the DUSK control slowly clockwise until the lamp illuminates Refer to previous section for more details Adjust the setting anti clockwise to lower the level of ambient light required for activation If you experience problems refer to Troubleshooting Guide If problems still exist do not immediately return the unit to store Tele...

Страница 9: ...oyance over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a unit or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light spread on all halogen floodlights can be reduced by angling the floodlight downwards on the mounting bracket This will also concentrate the li...