background image

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR 

IPS121

8

Power is changed in % of maximum power.

 

If "220V  30-20000kHz" submenu is selected in main MENU, you will see the submenu which 

allows work with signals in 30-20000kHz range outputted through "220V" socket to the power lines. This 

allows to fully imitate data transmission channel in 220V lines. 

With selection of line "Modulation OFF" it is possible to select modulation of carrier signal: FM, 

AM or PWM. 

If  FM  is  selected  "Frequency"  option  will  appear  allowing  selection  of  modulation  signal 

frequency. "Deviation" option will appear for FM allowing selection of highest deviation for modulated 
signal frequency from value of its carrier frequency

 

If  PWM  is  selected  two  options  will  appear:  "Frequency"  allowing  selection  of  frequency  of 

impulse and "Ratio" allowing selection of interval between impulses. 

Power is changed in % of maximum power. 

If "IR 940nm" submenu is selected in main MENU, you will see the submenu which allows work 

with IR emitter located on the front panel (Pic. 1 Pos. 7). 

With selection of line "Modulation OFF" it is possible to select modulation of carrier signal: FM, 

AM or PWM. 

If AM or FM is selected "Frequency" option will appear allowing selection of modulation signal 

frequency  (for  AM  and  FM  modulation).  "Deviation"  option  will  appear  for  FM  allowing  selection  of 
highest deviation for modulated signal frequency from value of its carrier frequency

 

If  PWM  is  selected  two  options  will  appear:  "Frequency"  allowing  selection  of  frequency  of 

impulse and "Ratio" allowing selection of interval between impulses. 

Power is changed in % of maximum power. 

Nonlinear element 

There are nonlinear elements connected to the contact pairs "1-2" and "7-8" of "RJ-45" socket in 

order to imitate nonlinearity in the wireline (Pic. 7). 

Содержание IPS121

Страница 1: ...TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121 1 IPS SIGNAL IMITATOR TECHNICAL DESCRIPTION AND OPERATING MANUAL ...

Страница 2: ...AL DESCRIPTION 4 1 1 Purpose of the device and main capabilities 4 1 2 Contents 4 1 3 Main module 4 1 4 Power supply 5 1 5 Operation modes 6 2 RESTRICTIONS AND RECOMMENDATIONS 9 3 TECHNICAL SPECIFICATIONS 9 4 LIFE TIME AND MANUFACTURER S WARRANTY 12 5 CERTIFICATE OF ACCEPTANCE 12 ...

Страница 3: ...STRUCTIONS FOR IPS121 3 Introduction Before starting your work with IPS121 carefully read this instruction and save it for further use as a handbook Any information in this manual can be changed fully or partially without further notice ...

Страница 4: ...cy Sound and ultrasound signals with user defined frequency or with frequency values corresponding to octave and third octave filters and direct connection of speakers to the IPS121 output socket Low frequency magnetic field Imitation of nonlinear transition in wire lines 1 2 IPS121 Contents 1 Main module 2 HF antenna 3 RJ 45 cable 4 220V cable 5 3 RJ 45 cable 6 Power supply charger 5V 1A 7 Techni...

Страница 5: ...kHz range ________________________________________________________________________ 1 4 IPS121 Power supply Battery status icon is located in upper right corner of main menu screen Fully colored icon corresponds to fully charged battery uncolored crossed with line discharged 1 4 1 Battery charging To charge internal battery connect power supply State of power switch has no effect on charging Chargi...

Страница 6: ...1 6 GHz range outputted through HF SHF socket intended for RF antenna Setting altering can be achieved using ROTARY KNOB with step selected in SETTING submenu Default value is 10 MHz If Modulation OFF is selected it will change carrier signal modulation type AM or FM as well as FHSS Frequency Hopping Spread Spectrum DSSS Direct Sequence Spread Spectrum and PULSE If AM or FM is selected Frequency o...

Страница 7: ...item Modulation OFF it is possible to select modulation of carrier signal FM AM or PWM If AM or FM is selected Frequency option will appear allowing selection of modulation signal frequency for AM and FM modulation Deviation option will appear for FM allowing selection of highest deviation for modulated signal frequency from value of its carrier frequency If PWM is selected two options will appear...

Страница 8: ...f impulse and Ratio allowing selection of interval between impulses Power is changed in of maximum power If IR 940nm submenu is selected in main MENU you will see the submenu which allows work with IR emitter located on the front panel Pic 1 Pos 7 With selection of line Modulation OFF it is possible to select modulation of carrier signal FM AM or PWM If AM or FM is selected Frequency option will a...

Страница 9: ...ONS HF SHF socket Frequency range MHz 100 6000 Frequency tuning step kHz 10 100 1000 10000 100000 Signal level dBm 42 14 Stray harmonics dBm 100 200MHz 15 200 700 1100 1500MHz 45 800 1000 1600 6000MHz 30 Signal Sinusoidal DSSS FHSS PULSE Modulation AM FM Data transmission standards imitation GSM 3G DECT WLAN BLUETOOTH Modulation frequency kHz 0 5 1 1 5 15 АМ depth 70 FM Deviation kHz 30 100 300 60...

Страница 10: ...quency range kHz 30 20000 Maximum signal amplitude V 3 5 Maximum input voltage V 380 Modulation FM DSSS Modulation frequency kHz 0 5 1 1 5 15 FM Deviation kHz 5 20 100 300 Frequency of PWM signal Hz 1 10 40 и 100 PWM Duty cycle 1 5 10 IR emitter Wave length nm 940 Subcarrier frequency range kHz 0 01 5000 Stray harmonics dBm 30 Output power mW 0 5 Modulation AM FM DSSS Modulation frequency kHz 0 5 ...

Страница 11: ... 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000 10000 12500 16000 20000 25000 31500 40000 50000 63000 80000 100000 Nonlinear distortion no more than 1 Modulation AM FM DSSS Modulation frequency kHz 0 5 1 1 5 15 АМ depth 15 FM Deviation kHz 5 20 100 300 Frequency of PWM signal Hz 1 20 PWM Duty cycle 1 5 10 Magnetic field emitter MF Equivalen...

Страница 12: ...ill follow exploitation transportation and storage regulations stated in this instruction Warranty period one year from the day of delivery to the customer 4 2 2 During warranty period manufacturer will provide free of charge repairs as long as consumer will follow exploitation transportation and storage regulations stated in this instruction 5 CERTIFICATE OF ACCEPTANCE IPS121 device Certified ___...

Страница 13: ...___ Manufactured ________________ Manufacturer s stamp Sold ___________________________________ Date ________ vendor s identification Salesman __________________ Vendor s stamp signature CARD STUB 1 For warranty repair maintenance IPS121 Serial ______________ Date ________________ Executor _______________________________ Family name signature ...

Отзывы: