TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR
IPS121
11
"LF" socket
Socket
Symmetrical
Frequency range, kHz
0.01-120
Maximum output power, W
0.7 (power supply),
0.3 (internal battery)
Power levels, %
7.5, 14, 20, 32, 50, 65, 80, 100
Impedance, Ω
8
Frequency-tuning step, kHz
1, 10, 100, 1000
Octave filters frequency values, Hz
32, 63, 125, 250, 500, 1000,
2000, 4000, 6000, 16000, 31500
63000
Third octave filters frequency values, Hz
32, 40, 50, 63, 80, 100, 125,
160, 200, 250, 315, 400, 500,
630, 800, 1000, 1250, 1600,
2000, 2500, 3150, 4000, 5000,
6300, 8000, 10000, 12500,
16000, 20000, 25000, 31500,
40000, 50000, 63000, 80000,
100000,
Nonlinear distortion, no more than, %
1
Modulation
AM, FM, DSSS
Modulation frequency, kHz
0.5, 1, 1, 5, 15
АМ depth, %
15
FM
Deviation, kHz
5, 20, 100, 300
Frequency of PWM signal
, Hz
1, 20
PWM Duty cycle
1, 5, 10
Magnetic field emitter «MF»
Equivalent magnetic moment of magnetic field source with frequency 1kHz, A*m
2
Power levels
100%
2*10
-4
7.5%
2*10
-5
Power
Power supply
Li-Polymer battery, 2.2A/h or 220V
power supply
Maximum current consumption, mA