6. Turn the engine switch to the “ON(I)” position.
Place one hand on the generator to hold it in
place, and pull on the recoil starter handle
slowly until a slight resistance is felt. Then pull
quickly to start the engine. Return cord gently
into the machine. Never allow the cord to snap
back.
Connecting Electrical Loads
LOW IDLE Switch
This unit has been pretested and adjusted to handle
its full capacity. Before starting the generator,
disconnect all loads. Apply load only after generator
is running. Voltage is regulated via the engine speed
adjusted at the factory for correct output.
Re-adjusting will void warranty.
NOTE:
Keep choke knob in “
START
” position for only 1 pull
of the recoil starter. After first pull, move choke knob
to the “
RUN
” position for up to the next 3 pulls of the
recoil starter. Too much choke leads to spark plug
fouling/engine flooding due to the lack of incoming air.
This will cause the engine not to start.
If engine starts after 3 pulls but fails to run. Or if unit
shuts down during operation, make sure unit is on a
level surface and check for proper oil level in
crankcase. This unit may be equipped with a low oil
protection device. If so, oil must be at proper level
for engine to start.
NOTE:
When applying a load, do not exceed the maximum
wattage rating of the generator when using one or
more receptacles. Also, do not exceed the amperage
rating of any one receptacle.
Do not apply heavy electrical load during break-in
period (the first five hours of operations).
1. Let engine stabilize and warm up for a few minutes
after starting.
2. Ensure circuit breaker on control panel is in on
position.
3. Plug in and turn on the desired 120 Volt AC, single
phase, 60Hz electrical loads. It is better to attach
the item with largest load first.
7. When engine starts, push the choke lever
in to the “RUN” position.
When starting engine, pull cord slowly until
resistance is felt and then pull rapidly to avoid
kickback.
Starter cord kickback (rapid retraction)
will pull hand and arm toward engine
faster than you can let go which could
cause broken bones, fractures, bruises,
or sprains resulting in serious injury.
WARNING
Always start the generator with LOW IDLE SWITCH
on OFF position. Allow the engine speed to stabilize
and the OUTPUT READY INDICATOR LED to
illuminate green before switching LOW IDLE Switch
to ON position.
NOTICE
8. Allow generator to run at no load for few minutes
upon each initial start-up to permit engine and
generator to stablize.
For periods of high electrical load or momentary
fluctuations, the LOW IDLE Switch should be turned
OFF.
NOTICE
Содержание SUA3800i
Страница 26: ...Page 24 PARTS DIAGRAM PARTS DIAGRAM AND PARTS LIST SUA3800i ...
Страница 32: ......
Страница 33: ......
Страница 34: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Страница 36: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Страница 65: ...Página 27 DIAGRAMA DE PIEZAS DIAGRAMA DE PIEZAS Y LIST SUA3800i ...
Страница 71: ......
Страница 72: ......
Страница 73: ......
Страница 74: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Страница 76: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Страница 104: ...Page 26 SCHÉMA DES PIÈCES SCHÉMA DES PIÈCES ET LISTE DES PIÈCES SUA3800i ...
Страница 110: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...
Страница 112: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...