Dimensional drawing
Light spot size
Safety instructions
Read the operating instructions before commissioning.
Connection, installation, adjustment and commissioning may only be performed by qualified personnel.
The device must not be used outdoors. Laserschutzklasse 1; Wellenlänge: 655nm; Frequenz; 5kHz, Pulsbreite: 3,2µs;
Grenzwert Puls: ≤ 2,3mW (IEC 60825
-1)
Complies with 21 CFR 1040.10 and 1040.11 except for deviations as specified in Laser Notice No. 56, May 2019.
Attention!
Use of controls or adjustments or performance of procedures other than those specified herein may
result in hazardous radiation exposure
Before commissioning, please make sure that all safety instructions in the product documentation, if applicable, have
been observed!
Not a safety component according to the EU Machinery Directive. The use of these products is prohibited if they have
a direct impact on personal safety.
Intended use
The sensor is used for optical non-contact detection.
Connection
Plug the connector onto a suitable cable socket in a voltage-free manner and screw it tight.
Connect the cable according to the connection diagram on page 1.
As soon as the operating voltage is applied, the green LED (LED 1) lights up.
Information on the connection of the white line (PIN 2):
1. Receiver: Connection with L+: Teach in analog to the respective specifications for the keystroke
Connection with L-: Teach button locked
No connection:
Normal operation - it is recommended to connect the line to a free terminal
during normal operation.
2. Transmitter:Connection with L+: Laser diode off
Connection with L- / no connection: Normal operation - it is recommended to connect the line
to a free terminal during normal operation.
Mounting
Mount the sensor on a suitable holder (e.g. universal holder AY000116).