manual pressure sensors
pag
e 17
ipf electronic gmbh
Kalver Str. 25 - 27
58515 Lüdenscheid - Germany
www.ipf-electronic.
com
Subject to alteration!
Tel +49 2351 9365-0
Fax +49 2351 9365-19
info@ipf-electronic.
com
Factory settings
OU 1
SP.rP
OU 2
4 - 20
SP 1
50% of nominal pressure
rP 1
10% of nominal pressure
SP 2
75% of nominal pressure
rP 2
10% of nominal pressure
technical data
pressure range [bar]
excess pressure [bar]
pressure pick-up
operating voltage
voltage drop
current consumption
switching outputs
time delay
operating position adj. range
release position
switching frequency
repeatability
current output
burden
error recognition
rise time
muting
linearity error
system pressure display
switching function display
operating temperature
temperature drift
conn. to pressure system
sensor head material
housing material
system of protection
electrical connection
optical interface
see list of articles
50% of nominal pressure (PN) for DW35 (6bar for DW36)
peak value memory every 2ms (display via PC)
12 to 32V DC, reverse polarity protection
(15 to 32V DC, if operated with voltage output
)
< 2V
< 60mA
2 x pnp-switching, no/nc 1A short circuit protection
0 to 20s, adjustable
1 to 100% of PN,
0 to 99% of PN
max. 125Hz
< ±0,1% of accumulated value
0/4 to 20mA, 20 – 0/4mA
max. analog outp
RL [W]=(Ub-8V) / 20mA
. if line breakage (current) - short-circuit (voltage ≥1V)
5ms (10% - 90% of PN)
0 to 20s, adjustable
max. ±0.25% of PN
4 x 7 segment LED-Display
2x LED red
-20°C to +80°C
< ±0,2% / 10K (-10°C to +70°C)
DW35: G1/4A, SW 22 (DW36: G1/8, SW 22)
stainless steel 1.4435 / ceramic
PA6.6, polyester
IP65 to EN 60529
M12 connector
,8
-pin
9600 Baud, via optical adapter at USB-Port