 IPEX 

(IP Electronix)

                

PH422Ex2

User’s Manual

 

 

Page 3 of 21 

                                                                          Doc No. : PH422Ex2-UM-001  

                                                                                                                                                                   14 January 2014 

1.

 

Introduction 

IPEX

 

PH422Ex2™

 

bidirectional communication terminal server/client is a simple solution for connecting serial 

devices to a network  which results in having 2 RS-422 (4-Wired RS-485) serial ports over Ethernet network 

which  is compatible with RS-422  standard  devices  differential  Tx+,Tx-  &  Rx+,Rx-  signals. This converter uses 

transparent communicate protocol, so it is not required to understand complex Ethernet TCP/IP protocol, and 

no modification in serial programs is needed. It operates as a Real COM, TCP Server or TCP Client Full-Duplex 

converter and supports bidirectional connection. 

PH422Ex2™

 is designed for industrial usage and is useful for connecting any device with a serial interface to a 

computer via Ethernet supported network like LAN, WAN … and can be used in Industrial Automation, 

Telecommunications, SCADA Systems, and DCS Systems …. 
Protection against Surge, ESD and EMI is implemented in its design and it has 3kV isolation between Ethernet 

and RS-422 sides.  

PH422Ex2

™ comes complete with drivers for Microsoft Windows XP/CE/2003/2008/7. Its setup file creates 2 

virtual COM Port on your Server, PC or Laptop with configurable baud rate, 8 bits data length and 1 stop bit 
fixed setting.  

2.

 

Specifications 

 

Number of Ports: 

#2 RS-422 Serial Port, #1 Ethernet RJ45 (10/100 Mbps) Port

 

 

Serial Standard:

 EIA RS-485, RS-422 Standard, Asynchronous Full-Duplex 4-Wire  

 

RS-422 Signals:

 Tx+, Tx-, Rx+, Rx-, GND 

 

RS-422 Baud Rates:

 300, 600, 1200, 2400, 4800, 9600, 19200 and 38400 bps; Selectable 

 

RS-422 Parity: 

Even, Odd, None, Mark and Space; Selectable 

 

Supports 

Point-to-Point

 and 

Multidrop

 Configuration  

 

Transmission Medium:

 Twisted Pair Cable or Shielded Wire 

 

Maximum Communication Distance:

 1200m (4000 feet)  

 

Loading:

 Supported up to 32 Nodes 

 

Network Protocols: 

ICMP, IP, TCP, UDP, DHCP, Telnet, DNS, SNMP, HTTP, SMTP, ARP

 

 

Windows Virtual COM Drivers: 

Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7 x86/x64,  

 

Power (Green)

 LED Indicator 

 

Transmit (Blue)

 and 

Receive (Yellow)

 LED Indicator for All Ports 

 

ESD Protection: 

RS-422 Bus-Pin ESD Protection Exceeds ±15 kV Using Human-Body Model (HBM)

 

 

Dimensions:

 36.41mm x 121.82mm x 140 mm (1.43inch x 4.79inch x 5.51inch) 

 

Operating Temperature:

 -10°C to +70°C (+14°F to +158°F) 

 

1 Year Guarantee

 and 

5 Years Support

 

Содержание PH422Ex2

Страница 1: ...Doc No PH422Ex2 UM 001 USER S MANUAL IPEX IP Electronix 14 January 2014 PH422Ex2 2 RS 422 Serial Port to Ethernet Terminal Server Client...

Страница 2: ...TIONS 3 3 PACKAGE CHECKLIST 4 4 TOP PANEL 4 5 FRONT PANEL 5 6 RS 422 CONNECTING METHODS 6 7 CONNECTION DIAGRAM 7 8 DEVICE NETWORK AND SERIAL PORT SETTINGS 9 9 NETWORK CONNECTION TESTING 12 10 CONNECTI...

Страница 3: ...ween Ethernet and RS 422 sides PH422Ex2 comes complete with drivers for Microsoft Windows XP CE 2003 2008 7 Its setup file creates 2 virtual COM Port on your Server PC or Laptop with configurable baud...

Страница 4: ...eneral Indicators POWER LED Green It is turned ON when the power supply connects to VDC and GND correctly SERVER LED Green It is turned ON if the device is in Server Mode CLIENT LED Green It is turned...

Страница 5: ...www ipelectronix com IPEX IP Electronix PH422Ex2 User s Manual Page 5 of 21 Doc No PH422Ex2 UM 001 14 January 2014 5 Front Panel...

Страница 6: ...w ipelectronix com IPEX IP Electronix PH422Ex2 User s Manual Page 6 of 21 Doc No PH422Ex2 UM 001 14 January 2014 6 RS 422 Connecting methods 6 1 14BRS 422 Point to Point 6 2 15BRS 422 Multi Drop Netwo...

Страница 7: ...ication software you want There are two methods in order to be connected to the PH422Ex2 COM Ports via Ethernet As the first way it is possible to connect to the device by opening a normal COM Port if...

Страница 8: ...her via Ethernet network you can use this connecting method Take two PH422Ex2 Set one PH422Ex2 as Server and another one as Client with adding Remote Server IP on it These two converters are connectin...

Страница 9: ...ort 1 of PH422Ex2 Now run a terminal emulator on your computer You can find some terminal emulators in the Utility folder in the installation CD For example we use Microsoft Hyper Terminal Run Hyperte...

Страница 10: ...on the Hyper Terminal Entering Device Network and Serial Ports Setting Menu IMPORTANT Now to enter device network and serial ports settings menu follow the below procedure step by step 1 Push the CONF...

Страница 11: ...lt settings in this page It is possible to change the entire network and serial ports settings from this menu For example if you want to change the IP Address of the device first press 1 enter new IP...

Страница 12: ...y the green and yellow LEDs on the PH422Ex2 s RJ45 socket will blink Now it is important to check the network wiring topology and testing all the cables routers switches in the route from PH422Ex2 to...

Страница 13: ...21 Doc No PH422Ex2 UM 001 14 January 2014 If there are any problems in the network you could not see response from the device If you see this timeout window you can t continue installation and first...

Страница 14: ...t numbers is as follow Port 1 9761 Port 2 9762 For example we connect to Port 1 by means of Hyper Terminal Run Hyperterm exe and from properties dialog box select TCP IP Winsock Enter device IP Addres...

Страница 15: ...he second method for connecting to PH422Ex2 serial ports is to install virtual COM port driver on your computer and open ports as a normal Windows COM port Run PHEx2_32bit exe if your Windows is 32 bi...

Страница 16: ...www ipelectronix com IPEX IP Electronix PH422Ex2 User s Manual Page 16 of 21 Doc No PH422Ex2 UM 001 14 January 2014 In this dialog box click on Next Now click on Install...

Страница 17: ...op any running application on your system and then from Windows Start Programs IPEX run PHEX2 exe Simply Enter PH422Ex2 IP Address and serial port number for Port 1 and Port 2 and then press apply For...

Страница 18: ...2 User s Manual Page 18 of 21 Doc No PH422Ex2 UM 001 14 January 2014 If during installation you see this Window Select Install the software automatically Recommended and click on Next Now click on Fin...

Страница 19: ...NOTICE If COM Port number you select is previously used by other application you cannot choose that port number for the device To see which COM Port is in use by the system run Device Manager and from...

Страница 20: ...EX IP Electronix PH422Ex2 User s Manual Page 20 of 21 Doc No PH422Ex2 UM 001 14 January 2014 Now you can see which COM port is free and which COM port is in use You must select COM port number for you...

Страница 21: ...arantee All products manufactured by IPEX are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser 14 Technical Support If you have...

Отзывы: