1 September 2019
7.2)
Null Modem Connection (to PC, PLC, RTU, A-380, or any other DTE devices)
PC,PLC or other DTE devices
DB9-Male Pin Number
PH232Ex1Plus Port as DTE
DB9-Male Pin Number
Pin 7: RTS
(Output)
Pin 1: DCD
(Input)
Pin 3: TxD
(Output)
Pin 2: RxD
(Input)
Pin 2: RxD
(Input)
Pin 3: TxD
(Output)
Pin 6: DSR
(Input)
Pin 4: DTR
(Output)
Pin 5: GND
(Ground)
Pin 5: GND
(Ground)
Pin 4: DTR
(Output)
Pin 6: DSR
(Input)
Pin 8: CTS
(Input)
Pin 7: RTS
(Output)
Pin 7: RTS
(Output)
Pin 8: CTS
(Input)
Pin 1: DCD
(Input)
Pin 7: RTS
(Output)
(Null Modem Cable)