IPC Eagle CT160 700 Скачать руководство пользователя страница 16

INTRODUCTION/GENERAL 
WARNINGS/SAFETY 
________________________________________________________________________________ 

p. 15 of 14 

 
 
 

 

a- battery voltage is 

 29V

a- charge the battery

a- battery voltage is 

 27V

a- check the battery levels and charge the battery

a- brushes are worn

a- replace the brushes

b- the floor is very smooth and the electronic 
doesn't read enough current consumption

b- pass from P3 to P2 or P1: if already P1, use the 
programming instruction to reduce the brushes pressure

a- parking brake is engage

a- unlock the brake by pushing the L shape lever near the 
pedal

b- brake microswitch is wrong fixed

b- check and eventually adjust the microswitch position

c- brake microswitch is broken

c- replace the microswitch

a- recovery tank level sensor is engage by the 
water level

a- empty the recovery tank and reset the machine ( key 
OFF/ON )

b- recovery tank level sensor is blocked in upper 
position

b- check the sensor and eventually replace it (code 
MECI00516)

a- solution tank level sensor is engage by the 
low water level

a- expect to empty the recovery tank and fill the solution 
tank

b- solution tank level sensor is blocked in lower 
position

b- check the sensor and eventually replace it (code 
MECI00516)

a- is more than 5 minutes that the solution tank 
level sensor is engage by the low water level

a- empty the recovery tank and fill the solution tank and 
reset the machine ( key OFF/ON )

b- is more than 5 minutes that the solution tank 
level sensor is blocked in lower position

b- check the sensor and eventually replace it (code 
MECI00516)

a- replacement of the potentiometer

a- use the programming instruction to align the new 
potentiometer

b- wrong ohm value in zero position 

b- set to 0

Ω 

in zero position and follow the remedy "a" to 

align it

8

BATTERY FLAT

OFF

OFF

ON

brush head low 

position 

microswitch 

inside the 

actuator

9

BATTERIA ESAURITA

OFF

OFF

ON

battery

OFF

battery

ON

microswitch in the 

parking brake 

pedal

10

BRUSHES WORN

11

PARKING BRAKE

ON

ON

ON

ON

12

RECOV.TANK LEVEL

ON

OFF

ON

level sensor 

inside the solution 

tank MECI00400

13

WATER RESERVE

ON

ON

ON

level sensor 

inside the 

recovery tank 

ON

level sensor 

inside the solution 

tank MECI00400

OFF

accelerator pedal 

potentiometer

14

NO WATER

15

POTENTIOMETER 

ALIGNMENT

OFF

OFF

OFF

OFF

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Содержание CT160 700

Страница 1: ...OPERATIONS MANUAL CT160 h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Страница 2: ...um gradient Bar code with serial number Manufacturer identification TABLE OF CONTENTS INTRODUCTION GENERAL WARNINGS SAFETY 2 UNPACKING 3 TECHNICAL SPECIFICATIONS 4 DESCRIPTION OF COMMANDS AND CONTROL...

Страница 3: ...C The optimal working temperature must be between 0 C and 40 C The humidity must be between 30 and 95 Do not use the machine in an explosive atmosphere Do not use the machine as a means of transport D...

Страница 4: ...a firm at work or during transfer are caused by failure to observe the most elementary safety rules A careful cautious user is the best guarantee against accidents and is more effective than any preve...

Страница 5: ...1600 2100 1600 2100 1600 2100 Cleaning solution automatic metering YES YES YES YES Safety code display Voltmeter YES YES YES YES Maximum gradient 16 16 16 16 Drive motor power W 560 560 560 560 Forwar...

Страница 6: ...5 Suction motor ON OFF 6 Recovery tank overflow level indicator 7 No cleaning solution indicator 8 Brush engagement release key not used in mod with roller head 9 Work program selection keys and indi...

Страница 7: ...ow be performed before operating the machine for this operation follow the directions in the relevant paragraph BATTERIES installation and connection Make sure that you fit only terminals marked with...

Страница 8: ...THE DISC BRUSHES Raise the machine side apertures on both sides and position the brushes below the compartment ensuring that they rest against the stops to align them with the engagement unit Insert...

Страница 9: ...he support as shown in the figure Connect the suction pipe to the squeegee The squeegee blades scrape the film of water and detergent thus permitting perfect drying In the long term the continuous fri...

Страница 10: ...cally disables all the functions except for the drive when the battery drops to a voltage of approx 29 volts indicating firstly battery low and then battery flat on the display In this case proceed wi...

Страница 11: ...ll automatically raise the squeegee and only once this has been done will the consent be given for operation Use of reverse gear is identified by a safety buzzer all the functions will remain active T...

Страница 12: ...le ON or OFF The parameter can be changed via the usual buttons and When the display button is pressed briefly the setting is stored and you go on to the next page 3 P1 Brush working pressure from 010...

Страница 13: ...same procedure as the one above is used MAINTENANCE Battery check and recharging Periodically check the level of the electrolyte inside the battery The battery compartment is below the operator s sea...

Страница 14: ...ps in reverse order ROUTINE MAINTENANCE SUMMARY TABLE Caution operation to be performed with the machine switched off and the key removed All routine or extraordinary maintenance operations must be pe...

Страница 15: ...RTRT00250 c replace the main card MECE00265 and the control panel MEQE00050 a pedal in pushed before key turning ON a release the pedal a the plug under the pedal bad connected a check and tight the...

Страница 16: ...tank and fill the solution tank b solution tank level sensor is blocked in lower position b check the sensor and eventually replace it code MECI00516 a is more than 5 minutes that the solution tank l...