nano3G AP Installation Manual
nano3G AP Hardware Installation
N3G_INST_300 v14.0 for N3G_2.85 © ip.access Limited 2012
Page 58
The antennas must be oriented perpendicular to the unit, as shown, so that the cover fits
correctly without stressing the connectors.
To fit external antennas, first remove the plastic cover from the antenna side of the unit.
Unscrew the antennas to expose the SMA connectors. Connect external antennas directly
to the SMA connectors. Route the cables out of the way of the antenna cover, then refit the
cover.
6.3.4
Commission the AP
Configure the AP so that it will connect to its serving NOS Server. If this has not been done
already, do this now, before installing the AP in its final location. For instructions, see
section 5.
6.3.5
Cable Connections
Two power supply modules are available from ip.access, designed for use with the
ip.access nano3G E8 AP and E16 AP, that are compliant with the IEEE 802.3at standard:
• The POE+ injector, as supplied, is commonly used for single site installations
• Direct power from the mains via an optional power adapter
POE+ Injector
The AP can be up to 100m from the switch/gateway to the backhaul, but allow
approximately 0.1m for routing through the injector. The injector can be positioned
anywhere on this cable run. Hence the injector can be at the most convenient point for
providing power, without restricting the location of the AP.
The injector takes a direct mains input using the supplied mains cable. Use a CAT5
Ethernet cable that is capable of carrying POE from the injector to the AP.
Injector
E8/E16
AP
POE+
Mains Input
Backhaul
Network to AC
Maximum total cable length
between nearest switch/gateway and AP is 100m
LAN Cable
to nearest
switch/gateway