303350 Installation Manual E-Series CMU 

 

Confidential 

Revision Date: 9-July-18 

 

Revision: H 

Process Owner:  Engineering 

 

Page 1 of 47 

 
   

 

   IONX Technical Data 

 

 

 

 

 
 
 
 
 
 

 Installation Manual 

for the 

Edge E-Series 

Communications Management Unit (CMU) 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

IONX LLC 

515 S. Franklin St. 

West Chester, PA 19382 

www.ionxlive.com 

484.653.2600

 

Содержание CMU-E4S

Страница 1: ...______________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engineering Page 1 of 47 IONX Technical Data Installation Manual for the Ed...

Страница 2: ...fect the performance of the device Unit shall be masked appropriately if post installation coating is required WARNING EXPLOSION HAZARD The equipment temperature Class is T4 and only certified for use...

Страница 3: ...ucun mat riau Le rev tement peut nuire aux performances de l appareil L unit doit tre masqu e de mani re appropri e si un rev tement post installation est requis ATTENTION DANGER D EXPLOSION La classe...

Страница 4: ...lling screws T 27 Tamper Resistant Torx driver Securing CMU to bracket If using a knife to cut the tape do not let the blade extend more than inch inside of the cardboard box 2 1 Inspect shipping box...

Страница 5: ...m with help in the subject line 3 1 2 If there is no reply contact the IONX Support Center Appendix C to get your email address set up to use TARA and IONXlive net 3 1 3 Download the IONX E series app...

Страница 6: ...reply within 60 minutes contact the IONX Support Center Appendix D to get your email address set up to use TARA and IONXlive net 4 2 Associating the Car Number to the CMU 4 2 1 Start a new email mess...

Страница 7: ...U o Period o The serial number of the new CMU being installed o Period o The Car initials o Period o The Car number which the CMU is installed on Example R OldSerialNumber NewSerialNumber CarInitial C...

Страница 8: ...nual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engineering Page 8 of 47 4 4 2 After logging in you should see the following screen This is the Install tab and should b...

Страница 9: ...ber format ABCD 123456 and choose the customer name from the dropdown Then press the Install button The following message should be displayed Success Unit Serial Number is now installed on Car Mark as...

Страница 10: ...on H Process Owner Engineering Page 10 of 47 4 4 4 If installing multiple devices please use the section at the bottom of the page Up to five 5 devices can be installed at one time Success messages wi...

Страница 11: ...RA commands not used during installation can be found in Appendix B 4 5 1 Uninstall Used when uninstalling IONX CMU devices from cars Enter the serial number and car name for the device to be uninstal...

Страница 12: ...ion H Process Owner Engineering Page 12 of 47 4 5 2 Change battery See Appendix F 4 5 3 Replace Used when replacing an IONX CMU device on a car with another IONX CMU Enter old CMU serial number to be...

Страница 13: ...g Page 13 of 47 4 5 4 Wireless Sensor Monitor WSM For information purposes only Car sets are CMU devices plus Wireless Sensor Nodes WSNs WSM is used to determine if a CMU is awake and all WSNs have jo...

Страница 14: ..._______________________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engineering Page 14 of 47 5 Miscellaneous Translat...

Страница 15: ...ket is required for CMU E4S and CMU E5S models when commissioning for use in potentially explosive atmosphere IONX part number 302262 Isolation mount bracket for ExS is approved for use in explosive a...

Страница 16: ...om _____________________________________________________________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engineeri...

Страница 17: ...ion Date 9 July 18 Revision H Process Owner Engineering Page 17 of 47 A 3 E4S and E5S Installation with Magnetic Bracket and Safety Tether Required Tools Materials for Safety Tether Tool Name Part No...

Страница 18: ...MPERFECTIONS THAT MAY PREVENT THE MAGNETS FROM MATING FLUSH AND SECURING TO THE RAILCAR SURFACE STEP 3 THREAD THE WIRE ROPE THROUGH THE FERRULE AND AROUND ONE OF THE BRACKET FEET AND BACK THROUGH THE...

Страница 19: ...___________________________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engineering Page 19 of 47 DIFFERENT TYPES OF P...

Страница 20: ...xlive com _____________________________________________________________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner En...

Страница 21: ...ive com _____________________________________________________________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engi...

Страница 22: ...e com _____________________________________________________________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engine...

Страница 23: ...____________________________________________________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engineering Page 23 o...

Страница 24: ...____________________________________________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engineering Page 24 of 47 A 7...

Страница 25: ..._____________________________________________________________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engineering...

Страница 26: ...___________________________________________________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engineering Page 26 of...

Страница 27: ...port Center Appendix D to make sure your email address is registered to use TARA and IONXlive net B 2 Install Validation using IONXlive net B 2 1 Navigate to www IONXlive net and login if a username a...

Страница 28: ...2 4 If the installation was completed successfully there should be a recent message from the device If the message does not show up on the website please contact the IONX Support Center Appendix D B 2...

Страница 29: ...Email Request to TARA B 3 3 Send the email message B 3 3 1 A response email will be sent from TARA confirming B 3 3 2 The subscription to TARA for the CMU B 3 3 4 Example Below Figure 12 B3 4 A secon...

Страница 30: ...nfidential Revision Date 9 July 18 Revision H Process Owner Engineering Page 30 of 47 Figure 13 Sample TARA Message B 3 5 TARA now is configured to monitor the CMU Repeat the process for all the CMUs...

Страница 31: ...t phone or any computer with email access C 1 Before starting C 1 1 Confirm your email address is set up in the IONX TARA system by emailing tara ionxlive com with help in the subject line C 1 2 If th...

Страница 32: ...ge confirming the installation will be sent from TARA See example email in below C 2 4 The CMU is associated with the car number The installation is complete The car now can be released into service T...

Страница 33: ...al 1 484 653 2600 press 1 for Customer Service Phone toll free 1 888 519 4050 Fax 1 484 653 2601 Email supportcenter ionxlive com D2 Forcing the CMU to call If there is a problem verifying messages on...

Страница 34: ..._______________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engineering Page 34 of 47 D4 Overview of CMU physical feat...

Страница 35: ...Center Appendix D so a Customer Service Representative can correct the home position of the CMU E 2 2 The CMU configuration is not set correctly The CMU may not have been configured to report open clo...

Страница 36: ..._____ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engineering Page 36 of 47 Appendix F Battery Replacement Required Tools Materials Tool Name...

Страница 37: ...hazardous Attention Le bo tier peut accumuler une charge lectrostatique Nettoyez le bo tier en pulv risant de l eau N utilisez pas de chiffon pour nettoyer le CMU Retirer la CMU dans une zone connue...

Страница 38: ..._________________________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engineering Page 38 of 47 F 3 Remove the lid and...

Страница 39: ...he battery pack and set aside WARNING DO NOT PLACE USED HAZARDOUS BATTERY PACKS IN THE TRASH THESE SHOULD BE TAKEN TO A RECYLCING FACILITY THAT CAN PROPERLY DISPOSE OF THEM ATTENTION NE PLACEZ PAS LES...

Страница 40: ...TTERY PACK 303406 UTILISER UNIQUEMENT SUR LES MOD LES IONX E4X E5X et E6X From your email account the one you have registered for the IONXLive web site with start a new email Enter TARA ionxlive net i...

Страница 41: ...ery to the core module F 11 Confirm device activation message was received using IONX E series phone application F 12 Tuck the serial and power cables in the case F 13 Place the lid on the base enclos...

Страница 42: ...E SCREWS COUNTER CLOCKWISE UNTIL YOU FEEL THEM CLICK INTO THE EXISTING THREAD BEFORE TIGHTENING TO ENSURE HOLE IS NOT RE THREADED FAILURE TO DO THIS WILL STRIP THE THREADS MISE EN GARDE TOURNER LENTEM...

Страница 43: ...cks If any part of the oring is removed the oring gland must be cleaned to be free of particulates G 3 Clean enclosure base top of oring surface with damp cloth G 4 Clean enclosure lid oring bump out...

Страница 44: ...ference that may cause undesired operation Num ro de certification d Industrie Canada IC 12436A CMUE5A s applique aux appareils CMU marqu s CMU E5X et CMU E5S Num ro de certification d Industrie Canad...

Страница 45: ...ential Revision Date 9 July 18 Revision H Process Owner Engineering Page 45 of 47 This device complies with Industry Canada s license exempt RSSs Operation is subject to the following two conditions 1...

Страница 46: ...e com _____________________________________________________________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engine...

Страница 47: ...______________________________________________________________________ 303350 Installation Manual E Series CMU Confidential Revision Date 9 July 18 Revision H Process Owner Engineering Page 47 of 47 I...