Maintenance Procedures
31
Maintenance Procedures
General Maintenance
………………………
31
Filter Replacement
………………………
32
RO Cleaning
………………………
38
Battery Charging
………………………
39
UV Lamp Replacement
………………………
41
Winterising and Storage
………………………
44
General Maintenance
Before any maintenance activities are undertaken care must be taken to ensure that all mains
electrical power has been removed. When replacing 12v electrical components such as
pumps etc. The battery must be isolated. Water pressure within filters and pipelines must also
be dissipated to avoid injury.
Do not open any connections or filter housings with pressure in the system or injury may
occur or damage to equipment
Battery Charging
Battery charging is automatic, however after periods of exhaustive discharging of the battery
it may be necessary to perform a recondition charge. This is a setting on the mains charger
that can be selected by 3 presses of the mode button. This will recondition the plates within
the battery and restore some of the batteries efficiency.
General Cleaning
It is good husbandry to maintain a clean environment for your pure water system. Regularly
cleaning the machine with a micro-fibre cloth and ensuring the surrounding area is kept clean
and dry will make for a more efficient system and create a more pleasant working
environment
Draining
If the holding tank is drained completely, on re-filling you may encounter an airlock in the
system before the delivery pumps. If this occurs simply attach a hose to the relevant pump
outlet port and suck to prime the pump.
DO NOT DO THIS WITH A RUNNING THERMOPURE™ SYSTEM
.
Содержание Zero PPB
Страница 1: ...1 Operators Manual...
Страница 5: ...Zero Weights Dimensions 5 Dimensions...
Страница 7: ...Machine Component Identification 7 Component Identification...
Страница 8: ...Machine Component Identification 8 Control Panel...
Страница 10: ...Machine Component Identification 10 Zero System Filters Removed...
Страница 13: ...Machine Component Identification 13 Filter Identification Zero PPB System...