System Operation
Initial Charging Cycle
The initial charging cycle is required as it calibrates the NeverDie BMS to the Battery Module for accurate State of Charge
percentage monitoring. During the initial charging cycle, the system must reach a voltage level that is equal to the Standard
Full Charging Voltage indicated. Enable the charging device(s) so that they may complete a charge cycle. It is recommended
to not have any discharge loads active during the initial charging cycle, especially towards the end of charging.
Discharging
Discharging may be performed at any time the system is powered On.
NOTE - The Lithium Battery System will disconnect power if the voltage, amperage, or temperature limits are exceeded during
discharging. This NeverDie feature allows the system to have a “reserve” amount of energy left in the battery. Once the system is
discharged to 12.0V or 10% State of Charge, whichever comes first, power will be disabled to leave a “reserve” amount of energy
still left in the battery. To enable the remaining reserve energy of the system, short press the Power switch for 1 second.
NOTE - Once the reserve range is enabled the battery should be charged as soon as possible.
WARNING -
If the reserve energy is used and the battery module is left in a deeply discharged state without immediate
charging, the battery module will become permanently damaged.