![ionGen GTX12V630A-E2112-CS200 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/iongen/gtx12v630a-e2112-cs200/gtx12v630a-e2112-cs200_installers-manual_2087550009.webp)
Inverter Diagram
LITHIONICS BATTERY, CLEARWATER, FL 33765 USA | PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.com
7
The inverter diagram depicts a typical AC installation. The main panel has an output
breaker for the non-inverter loads. It is used to power the high power loads that are
beyond the inverters capacity such as a water heater or an electric stove. The AC input
must be protected a magnetic circuit breaker rated at 50A or less, and the cable cross-
section must be sized accordingly. Make all connections using proper crimp-on
connectors (do not use twist on connectors).
The inverter has a power assist feature and when enabled can add up to 2kVA (2000 /
120 = 17A) to the output during periods of peak power requirement. Together with a
maximum input current of 50A this means that the output can supply up to 67A (50+17).