Solar Diagram

LITHIONICS BATTERY, CLEARWATER, FL 33765 USA | PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.com

12

The Victron Smart Solar MPPT solar charge controller uses maximum power point tracking that optimizes the match between the
solar array and the battery bank. It converts the higher voltage DC output from the solar panels down to the lower voltage needed
to charge the batteries. The PV solar array is connected to the MPPT charger with a circuit breaker (not supplied). The specified
circuit breaker is only rated at 48VDC; if your PV solar array has an open circuit voltage that is higher, then another circuit breaker
with a higher voltage rating must be substituted. 

The charger is connected to the positive distribution buss via a 40A fuse. The fuse and wire sizes are based on the Victron MPPT
100/30
 charge controller, if a larger controller is used then the fuse and wire sizes should be increased as required. 

Using the VictronConnect App on your smartphone you can connect via blue tooth and remotely control and monitor the Smart
Solar MPPT
 charger.

Содержание GTX12V630A-E2112-CS200

Страница 1: ...LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com Revision 01 Installer s Guide GTX12V630A E2112 CS200 INSTALLATION KIT VICTRON 3000 WATT...

Страница 2: ...INVERTER DIAGRAM STERLING DIAGRAM SOLAR DIAGRAM BATTERY IONGAGE DIAGRAM PARTS LIST BATTERY INSTALLATION EQUIPMENT MANUALS Table of Contents LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 F...

Страница 3: ...ical codes Assume that voltage is present at the battery terminals use insulated tools and gloves while working on the system Always turn off equipment connected to the battery in addition to turning...

Страница 4: ...ery 630amp hours and a Victron MultiPlus 3000 watt inverter This combination is capable of providing enough power to run your AC loads for extended periods of time It is recommended to operate the bat...

Страница 5: ...in Diagram Inverter Diagram Sterling Diagram Solar Diagram Battery IonGage Diagram Wiring Diagrams LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com...

Страница 6: ...should be mounted as close as possible to the positive distribution buss The isolation switch allows you to isolate the inverter in case of a malfunction as well as disabling the inverter if you need...

Страница 7: ...is connected to the positive distribution buss via a 40A Maxi fuse The PV solar array is connected to the MPPT charger via a circuit breaker The specified circuit breaker is only rated at 48VDC if you...

Страница 8: ...MAIN DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 6...

Страница 9: ...apacity such as a water heater or an electric stove The AC input must be protected a magnetic circuit breaker rated at 50A or less and the cable cross section must be sized accordingly Make all connec...

Страница 10: ...esidual Current Device type GFCI receptacles must be used at all AC outlets The inverter is provided with a ground relay that automatically connects the neutral output to the chassis if no external AC...

Страница 11: ...INVERTER DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 9...

Страница 12: ...V input to 12V output up to 60amps The Sterling Battery to Battery charger charges the house battery via the vehicle s alternator This system uses either the Sterling BB1230 charger Mercedes recommend...

Страница 13: ...STERLING DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 11...

Страница 14: ...e MPPT charger with a circuit breaker not supplied The specified circuit breaker is only rated at 48VDC if your PV solar array has an open circuit voltage that is higher then another circuit breaker w...

Страница 15: ...SOLAR DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 13...

Страница 16: ...ta will only be correct if the configuration parameters are set correctly which are pre set initially by Lithionics Battery but are user adjustable with supporting hardware The SOC Gauge will also tra...

Страница 17: ...BATTERY IONGAGE DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 15...

Страница 18: ...QTY PART NUMBER DESCRIPTION COMMENTS Parts List LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 16...

Страница 19: ...nto the Power button to make sure it is completely off If the LED is on or blinking press and hold the Power button for 3 seconds until LED turns off Lithium batteries do not release gas during normal...

Страница 20: ...h resistance path and cause excessive heating of the connection which could then lead to permanent battery damage or fire If you must attach more than one lug to each terminal make sure at least 1 4 o...

Страница 21: ...r correct cable size which can be located at www nfpa org The battery circuit must be properly fused to handle the expected load and not to exceed the battery specifications After installation is comp...

Страница 22: ...r the manufacturer equipment manuals LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com Equipment Manuals Victron Inverter Victron MPPT Solar Charger...