Software Download

Power Master management software provides a user-friendly 
interface for your power systems. The graphic user-interface is 
intuitive and displays essential power information at a glance. 
Please follow procedures below to install the software.

Power Master

System

Summary

UPS

Status

Information

Configuration

Diagnostics

Load

Input

Status

Voltage

Frequency

Normal

229.9V

49.90Hz

Event Action

Events

Recipient

Settings

Logs

Events Logs

Status Records

Settings

Schedule

Shutdown

Output

Status 

Voltage

Frequency

Load

Normal / Eco Mode

230.0V

49.90Hz

0% (0 Watts)

Battery

Status 

Capacity

Normal /Charging

46%

UPS  Status

INSTALLATION PROCEDURE:

1.  Download  Power  Master  from  the  website:                                                                        

http://www.powermonitor.software/

2.  Double-click the file and follow the installation 

steps.

3.  When your computer restarts, the Power 

Master software will appear as a blue icon 
located in the system tray.

Содержание F15R

Страница 1: ...info ionups com au www ionups com au P 1300 700 805 ION F15R 1RU Line interactive 650 1200 1600VA User Guide...

Страница 2: ...ION F15R 1RU...

Страница 3: ...__ 4 Routine Maintenance and Storage___________ 5 Important Safety Instructions_______________ 6 Basic Operation__________________________ 7 Software Download______________________ 8 Technical Specifi...

Страница 4: ...battery for at least 8 hours is recommended to ensure that the battery s maximum charge capacity is achieved Charge loss may occur during shipping and storage To recharge the battery simply leave the...

Страница 5: ...l not be operated for long periods of time 1 First turn off your UPS and disconnect its power cord from the wall outlet Disconnect all cables connected to the UPS to avoid battery drain 2 The UPS shou...

Страница 6: ...rt equipment microwave ovens or vacuum cleaners to UPS Do not plug the UPS input into its own output Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liq...

Страница 7: ...nnection and communication from the DB9 serial on the computer to the UPS unit The UPS communicates its status to the software ION F15R 1RU Line interactive UPS 650 1200 1600VA 6 USB Port This port al...

Страница 8: ...oad Input Status Voltage Frequency Normal 229 9V 49 90Hz Event Action Events Recipient Settings Logs Events Logs Status Records Settings Schedule Shutdown Output Status Voltage Frequency Load Normal E...

Страница 9: ...VR 118 Buck Ratio AVR 85 Ac voltage regulation batt mode 10 Frequency Range batt mode 50 60 1 Hz Transfer time 4ms typical waveform batt mode Pure Sine Wave Outlet IEC 4 THDv 5 Linear Load Full protec...

Страница 10: ...cement YES INDICATORS Display LCD Alarm Battery mode Sounding every 30 seconds Low Battery Sounding every 2 seconds Over Load Sounding every 0 5 seconds Fault Continuous sounding PHYSICAL Dimensions W...

Страница 11: ...T Voltage V Line mode Bat mode Alarm Fault Sound disable Press the mute key 3s to disable and enable the buzzer sound Bat mode battery capacity Line mode 1 Battery charging cycle lighting 2 Battery fu...

Страница 12: ...wer to outlets Beep 1 time In Every 2 Seconds Utility Failure The UPS is providing battery power The rapid beeps indicate the battery will run out of power shortly Beep 1 time In Every 0 5 Second Over...

Страница 13: ...PS Connect power cord then turn the UPS on Make sure that your spare fuse meets the specification Batteries are discharged Allow the unit to recharge for at least 4 hours Unit has been damaged by a su...

Отзывы: