background image

OPERATION MANUAL

Dated: 04/09/2018

Document Name: WC33_OM

Page 6 of 8

www.ionproducts.net

Ion

®

 Digital Level Control 

Digital Level Control Switch

T

ROUBLESHOOTING

Switch Does Not Turn On Pump

1.  Test the pump without the Ion

®

 switch

a.  Plug the pump directly into the wall outlet, 

without plugging it into the switch plug.

b.  If pump still does not run, see the 

troubleshooting section in the pump 

manual.  

c.  If the pump does run, continue to the next 

step.

2.  Test the switch with the pump 

a.  Plug the pump into the Ion

®

 switch and 

plugging the Ion switch plug into the wall. 

b.  Push up on the sensing plate through the 

center hole on the underside of the switch.  

Note that, being an electronic switch, you 

will not hear a clicking sound. 

c.  If the pump does not turn on, the switch will 

have to be replaced.  

d.  If the pump does turn on, continue to the 

next step. 

3.  Verify the range of the switch 

a.  The part number can be found on the 

switch cord tag.

 

 

i.

 

IN-006… = 6” range

 

ii.

 

IN-085... = 8.5” range

 

iii.

 

IN-010… = 10” range (for special 

 applications)

b.  For a pipe-mounted switch, see Page 2, 

Installation Drawing to verify that the On 

level is appropriate for your basin. 

i. Lower the switch on the pipe so the 

On level is at a point within the basin, 

insuring that the Off level does not fall 

below the minimum level shown in the 

Installation Drawing. 

ii. If the On level is still too high, the switch 

will have to be replaced with a lower 

range Ion

®

 switch. 

c.  For a pump-mounted switch, see Page 

2, Figure D to verify that the On level is 

appropriate for your basin.

i. If the On level is too high, the switch will 

have to be replaced with a lower range 

Ion switch.  

Switch Does Not Turn Off Pump

1.  Unplug the pump from the Ion

®

 plug and then 

unplug the Ion plug from the wall outlet.

2.  Plug the pump back into the Ion

®

 plug and plug 

the Ion plug back into the wall outlet.

a.  If the pump does not turn on right away, and 

the water level is not at the On level, let the 

pump go through an On / Off cycle a few 

times to insure that the switch is functioning 

properly.  The basin may need to be filled 

with a garden hose or bucket.

b.  If the pump turns on right away, and the 

water level is not at the On level, the switch 

will have to be replaced. 

W

ARRANTY IS

 VOID 

IF...

1.  Using an extension cord.

2.  Power cord has been cut or the grounding 

prong removed or using an adapter fitting.

3.  The switch has been disassembled or tampered 

with.

4.  Any tags or labels have been removed.

5.  Used in a heavy grease application

6.  Used in applications exceeding the designed 

temperature range of 32  - 104 degrees F.

Содержание WC33

Страница 1: ...This system is not intended for use in hazardous locations per NFPA 70 National Electric Code Do not pump flammable liquids Consult factory for optional equipment rated for hazardous location use WARN...

Страница 2: ...the floor and you must unplug the pump or make any adjustments Pump Servicing Note Automatic thermal overload protects the sealed in oil motor Running dry may overheat the motor and activate the over...

Страница 3: ...s 1 Inlet in pump base may be clogged Remove pump and clean out openings 2 Impeller or volute openings may be plugged or partially plugged Remove pump and clean out 3 Pump impeller may be partially cl...

Страница 4: ...6 or 8 5 depending on your switch s range to find the On level Please refer to the Installation Drawing CAUTION Bottom of switch should not be mounted lower than suction inlet of pump When installing...

Страница 5: ...ectrical codes WARNING Electrical outlet must not be located in pump pit For best performance do not use electrical extension cords INSTALLATION DRAWING Lowest pump off level BE SURE TO MOUNT THE ION...

Страница 6: ...the On level is at a point within the basin insuring that the Off level does not fall below the minimum level shown in the Installation Drawing ii If the On level is still too high the switch will ha...

Страница 7: ...OPERATION MANUAL Dated 04 09 2018 Document Name WC33_OM Page 7 of 8 www ionproducts net Ion Digital Level Control Digital Level Control Switch Notes Notes...

Страница 8: ...ect a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unless...

Отзывы: