Ion+

®

 Connect

Digital Level Control Switch With Alarm

OPERATION MANUAL

Dated: 07/18/2017

Document Name: Ion+Connect_OM

Page 8 of 12

www.ionproducts.net

LED Explanations

Power LED

Condition

Normal

battery ok, AC ok

Solid GREEN

battery charging, AC ok

Blinking GREEN (1s on, 1s off)

Trigger alarm

Loss of power

Blinking AMBER (0.1s on, 0.9s off)

battery low

Alternate blinking AMBER and RED (RED ON, GREEN 0.5s on, 1.5s off)

battery critically low

Blinking RED (0.1s on, 0.9s off)

Pump LED

Condition

Normal

pump off

Off

pump on

Solid AMBER

Trigger alarm

no pump

Blinking AMBER (0.5s on, 0.5s off)

pump fail

Blinking AMBER (1s on, 1s off)

Alarm LED

Condition

Normal

no alarm

Off

Triggered alarm

alarm

Fast-blinking RED (0.3s on, 0.3s off) w/ Buzzer

silence

Slow-blinking RED (1s on, 1s off) w/o Buzzer

Buzzer interval same as fast-blinking RED (0.3s on, 0.3s off)

Cell LED

Condition

Normal

locked, good signal strength Solid GREEN

Triggered alarm

locked, low signal strength

Solid AMBER

locked, not in network

Solid RED

unlocked

Alternate Blinking AMBER and RED (RED LED on, GREEN 1s on, 1s off)

Содержание Ion+ Connect

Страница 1: ...signal POWER PUMP ALARM CELL PUMP TEST SILENCE RESET LOCK UNLOCK REMOTE ALARM CONTACT REMOTE ALARM INPUT DIGITAL LEVEL SENSOR W W W I O N P R O D U C T S N E T INPUT 120VAC 60HZ 15A OUTPUT 120VAC 60H...

Страница 2: ...sor 9 Remote Alarm Contact Normally closed dry contacts via 6P2C RJ14 jack 10 Remote Alarm Input Aux alarm input connection via 6P2C RJ14 jack Installation NOTE IF YOU ARE INSTALLING THE ION CONNECT W...

Страница 3: ...phone number of the Ion Connect for the contact Phone 555 987 6543 Serial 123456789 5 5 8 2 3 16 4 3 16 Dia Mounting Holes Phone 555 987 6543 Configuration NOTE Do not install the lithium ion battery...

Страница 4: ...lows Ph1 Your Cell Phone Number Example Ph1 5551234567 NOTE The phone number must be 10 digits long which includes the area code c When the Ion Connect receives the message it will respond with a text...

Страница 5: ...ump Test will manually run pump b Holding it for 3 seconds will send a notification to those in the list 2 Test Your Ion Sensor a Fill the sump pit with water b Confirm the water is pumped out of the...

Страница 6: ...nowledgments alert mode dialer Notifies phone numbers one at time acknowledgements alert delay alert delay 5 In alert mode Sets time in Minutes between sending alerts In dialer mode Sets time in Minut...

Страница 7: ...ed alarm conditions alarm relay out temp Relay output based on temp related alarm conditions alarm relay out batt Relay output based on battery related alarm conditions alarm relay out power Relay out...

Страница 8: ...low Blinking RED 0 1s on 0 9s off Pump LED Condition Normal pump off Off pump on Solid AMBER Trigger alarm no pump Blinking AMBER 0 5s on 0 5s off pump fail Blinking AMBER 1s on 1s off Alarm LED Cond...

Страница 9: ...mercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio...

Страница 10: ...Ion Connect Digital Level Control Switch With Alarm OPERATION MANUAL Dated 07 18 2017 Document Name Ion Connect_OM Page 10 of 12 www ionproducts net Notes...

Страница 11: ...Ion Connect Digital Level Control Switch With Alarm OPERATION MANUAL Dated 07 18 2017 Document Name Ion Connect_OM Page 11 of 12 www ionproducts net Notes...

Страница 12: ...orrect a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unle...

Отзывы: