background image

Ion+

®

 Connect

Digital Level Control Switch With Alarm

OPERATION MANUAL

Dated: 07/18/2017

Document Name: Ion+Connect_OM

     Page 9 of 12

www.ionproducts.net

15.21 Information to User

Changes or modifications not expressly approved by Metropolitan Industries will void the user’s authority to operate 

the equipment.

15.105 Information to User

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 

part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 

when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate 

radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful 

interference in which case the user will be required to correct the interference at his own expense.

Optional External Connections

Ion+ Connect

Remote

Alarm

Input

Two centermost

pins, maximum
5 VDC, < 2 mA

Remote

Alarm

Contact

Two centermost

pins, maximum

30 VAC/DC, 1 A

Optional
External

Device to

be Monitored

by Ion+ Connect

Optional
External

Alarm System 

to Monitor

Ion+ Connect

Either circuit inside the Ion+ Connect may be configured via 
cellular phone to be normally open or normally closed (see 
Command Summary).

Содержание Ion+ Connect

Страница 1: ...signal POWER PUMP ALARM CELL PUMP TEST SILENCE RESET LOCK UNLOCK REMOTE ALARM CONTACT REMOTE ALARM INPUT DIGITAL LEVEL SENSOR W W W I O N P R O D U C T S N E T INPUT 120VAC 60HZ 15A OUTPUT 120VAC 60H...

Страница 2: ...sor 9 Remote Alarm Contact Normally closed dry contacts via 6P2C RJ14 jack 10 Remote Alarm Input Aux alarm input connection via 6P2C RJ14 jack Installation NOTE IF YOU ARE INSTALLING THE ION CONNECT W...

Страница 3: ...phone number of the Ion Connect for the contact Phone 555 987 6543 Serial 123456789 5 5 8 2 3 16 4 3 16 Dia Mounting Holes Phone 555 987 6543 Configuration NOTE Do not install the lithium ion battery...

Страница 4: ...lows Ph1 Your Cell Phone Number Example Ph1 5551234567 NOTE The phone number must be 10 digits long which includes the area code c When the Ion Connect receives the message it will respond with a text...

Страница 5: ...ump Test will manually run pump b Holding it for 3 seconds will send a notification to those in the list 2 Test Your Ion Sensor a Fill the sump pit with water b Confirm the water is pumped out of the...

Страница 6: ...nowledgments alert mode dialer Notifies phone numbers one at time acknowledgements alert delay alert delay 5 In alert mode Sets time in Minutes between sending alerts In dialer mode Sets time in Minut...

Страница 7: ...ed alarm conditions alarm relay out temp Relay output based on temp related alarm conditions alarm relay out batt Relay output based on battery related alarm conditions alarm relay out power Relay out...

Страница 8: ...low Blinking RED 0 1s on 0 9s off Pump LED Condition Normal pump off Off pump on Solid AMBER Trigger alarm no pump Blinking AMBER 0 5s on 0 5s off pump fail Blinking AMBER 1s on 1s off Alarm LED Cond...

Страница 9: ...mercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio...

Страница 10: ...Ion Connect Digital Level Control Switch With Alarm OPERATION MANUAL Dated 07 18 2017 Document Name Ion Connect_OM Page 10 of 12 www ionproducts net Notes...

Страница 11: ...Ion Connect Digital Level Control Switch With Alarm OPERATION MANUAL Dated 07 18 2017 Document Name Ion Connect_OM Page 11 of 12 www ionproducts net Notes...

Страница 12: ...orrect a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unle...

Отзывы: