Post Install
The following general workflow outlines the tasks that will need to be done after the install of
ioiboxes. These post install procedures are mentioned in this document but are covered in greater
detail in the ioibox HTML Edition Setup User Guide. Please refer to these guides for more detail.
1. Configure the unit using its built in HTML setup application. Configure the unit, and
camera including Relay Outputs, Alarm Inputs, etc. For more information, refer to the
ioibox HTML Edition Setup User Guide.
2. Connect monitoring computers with a supported web browser or supported RTSP
device. If using analog only connect to the analog monitors.
Overview of Alarm Inputs (Dry Contacts)
Alarm Inputs of the ioiboxes allow interaction among the ioiboxes, cameras, and external devices.
The units can receive input signals (dry contact close/open) from external devices. For example,
fire alarms, PIR, magnetic sensors, fence sensors, break glass stations, control valve sensors,
mercury switches, etc and use them for triggering automatic actions.
CAUTION
To avoid damage to the system and system interference, a certified electrician must assure
that the ground voltage (ground loops) is comparable among all connected system
components.
CAUTION
Assure the common ground terminal connection for alarm inputs is connected in the right
terminal connector socket of an Alarm Input pair
Specification:
Dry Contacts (max. 24VDC 100mA) IN
Overview of Relay Outputs
An external device can be connected to the Relay Output terminal block of the unit. In response to
events such as alarm inputs, intruder alarms, poor visibility, etc. signals can be sent to operate
external devices.
CAUTION
To avoid damage to the system and system interference, a certified electrician must assure
that the ground voltage (ground loops) is comparable among all connected system
components.
27