33
VICTOREM
2KSDI-Mini User's Manual
6.11.4 Chromatic Error Correction
Enabling this correction reduces chromatic errors along sharp edges.
6.11.5 Test Pattern
The test pattern is a set of six vertical bars. From left to right the colors are: white, yellow, cyan, green,
magenta, red, and blue. The dynamic pattern adds a moving vertical line and a moving horizontal line.
6.11.6 Flat Field Correction
For lenses that do not evenly illuminate the camera's sensor, the Victorem 2KSDI-Mini cameras
include a flat field correction algorithm. Once calibrated, the flat field correction can eliminate lens
vignetting. Up to 4 different corrections can be stored in the camera's non-volatile memory. Use the
following procedure to calibrate and load a flat field correction.
1. Set up the lens as it is to be used for shooting, including desired aperture, for best results.
2. Point the camera at an evenly illuminated and colored scene such as a white sheet of paper or a
plain, out of focus wall.
3. Set the exposure time so the scene is a medium gray, with no pixels saturated or black.
4. Click the Start button in the Flat Field Correction section.
5. Save the correction by clicking the Save button and selecting a location. The stored correction
can be renamed by clicking the Rename button.
6. Load a correction by clicking the load button and selecting the desired correction location.
6.11.7 Temperatures
Displays the current temperature of the camera's FPGA and sensor. Note that RS model cameras are
unable to report the sensor temperature.
6.11.8 Bad Pixel Replacement
The bad pixel replacement algorithm should always be enabled. To export a text file containing a list of
bad pixels, click Export. Click Import to import a list of bad pixels from a text file.
6.11.9 Save/Load Configuration
The Victorem SDI Control can save a camera configuration to a file. Use the Save and Load buttons to
save or load configurations.
IO Industries Inc.
Revision 3.0