47
Troubleshooting
Operation problems can be due to a variety of causes. The first step in solving them is to make
sure that all cables are securely attached and seated completely in their sockets.
Symptom
Possible Cause
Action
No indication and no alarm, even
though the mains is normal
The AC input power is not
connected well
Check if input power cord
is firmly connected to the
mains
The AC input is connected
to the UPS output
Connect AC input power
cord to AC input correctly
Icon
and
warning code
flash on LCD display
Alarm beeps every 2 seconds
EPO function is activated
Set the circuit in closed
position to disable EPO
function
Icon
and
and
warning code
flash on LCD
display
Alarm beeps every 2 seconds
Line and neutral
conductors of UPS input
are reversed
Rotate mains power
socket by 180degree
and then connect to UPS
system
Icon
and
and
Warning code
Flash on LCD display
Alarm beeps every 2 seconds
The external or internal
battery is incorrectly
connected
Check if all batteries are
connected well
Fault code is shown as 27 on LCD
display
Alarm continuously beeps
Battery voltage is too high
or the charger is fault
Please contact your dealer
Fault code is shown as 28 on LCD
display
Alarm continuously beeps
Battery voltage is too low
or the charger is fault
Please contact your dealer
Содержание GBB1000N
Страница 2: ......
Страница 52: ... 2020 IOGEAR ...