Overview
Installation
Operation
Maintenance
Warranty
4. Installation semi – cased (1 duct for air exit).
non heated room with ambient temperature > 5° C and insulated to the
heated rooms of the dwelling.
Parameter « Air pipes » to be set on « Inner/Outer ».
Recommended room = underground or partially underground, room where
average yearly temperature is > 10° C°.
The pressure reduction in the room generated by the air extraction causes fresh air entry through
doors and windows. Plan an air entry (Ø 160mm) from outside to avoid air sucking from heated
living area.
In winter time the renewed air can cool the room.
Keep a free space of 500 mm in front of electric compartment and 300 mm around hydraulic
connections to allow easy access for maintenance.
670mm
mini
Examples :
•
Garage : recovery of free calories from combustion engine or of domestic
devices
•
Washing room : reduce humidity of the room and recover lost calories of
washing machine and dryer.
Inner/Outer
12