Get to know MSK-101-MM
Interfering materials
Below is a list of materials that could impact the
sensor performance if they hide it:
l
surfaces having metal-based paints or
carbon-based paints
l
tinted windows
l
surfaces having EMI/RFI glasses or mirrors
l
surfaces with water pipes, cables
l
tiles having metal-based glaze including
blue cobalt
l
metal screen foil
l
foil-backed insulation materials (e.g. foil)
l
foil moist materials (e.g. cork)
How to install several sensors
Three possible combinations of sensor
installation and the minimum distances to
maintain between the sensors with the sensors
aligned are presented as follows. Respecting
these distances guarantees the performance
levels indicated in section "Field of vision" on
page 8.
NOTICE
: other combinations are possible, but their
performance must be validated in the field.
Front-front combination
Front-back combination
Back-back combination
Note
: the blind spot created in this combination is very
wide. If possible, use the back-front configuration.