![Invest MSC-24/QD FP Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/invest/msc-24-qd-fp/msc-24-qd-fp_service-manual_2085183035.webp)
33
9.3 Key parts checking.
9.3.1. Compressor checking (Model:
DA150S1C-20FZ)
Measure the resistance value of each winding by using the multi-meter.
Position
Resistance Value
Blue - Red
0.95
Ω
Blue -
Black
(20
Ԩ
)
Red - Blue
9.3.2 Outdoor Fan Motor (Model: YDK53-6N)
Measure the resistance value of each winding by using the multi-meter.
Position
Resistance Value
Black -
Red
113
Ω
(20
Ԩ
)
Red
-Yellow
113
Ω
(20
Ԩ
)
Red -Blue
193
Ω
(20
Ԩ
)
Содержание MSC-24/QD FP
Страница 8: ...6 3 Dimension 3 1 Indoor Unit MSC 24 QD FP MSH 24 QD FP...
Страница 9: ...7 3 2 Outdoor Unit MSC 24 QD FP...
Страница 11: ...9 5 Refrigerant cycle diagram...
Страница 12: ...10 6 Wiring diagram 6 1 Indoor Unit MSC 24 QD FP MSH 24 QD FP...
Страница 13: ...11 6 2 Outdoor Unit MSC 24 QD FP...
Страница 37: ...35...