Invertek Drives OPTIDRIVE E3 Series Скачать руководство пользователя страница 11

Technical Data

Environment

Operational ambient temperature range  
Enclosed Drives: 

-20 ... 40°C (frost and condensation free)

Storage ambient temperature range:   -40 … 60°C
Maximum altitude:  

2000m. Derate above 1000m: 1% / 100m

Maximum humidity: 

95%, non-condensing

Rating Tables

Frame 

Size

kW

HP

Input 

Current

Fuse/MCB  

(Type B)

Maximum Cable 

Size

Output 

Current

Recommended 

Brake Resistance

Non UL

UL

mm

AWG

A

Ω

110 - 115 (+ / - 10%) V 1 Phase Input, 230V 3 Phase Output (Voltage Doubler)

1

0.37

0.5

7.8

10

10

8

8

2.3

-

1

0.75

1

15.8

25

20

8

8

4.3

-

2

1.1

1.5

21.9

32

30

8

8

5.8

100

200 - 240 (+ / - 10%) V 1 Phase Input, 3 Phase Output

1

0.37

0.5

3.7

10

6

8

8

2.3

-

1

0.75

1

7.5

10

10

8

8

4.3

-

1

1.5

2

12.9

16

17.5

8

8

7

-

2

1.5

2

12.9

16

17.5

8

8

7

100

2

2.2

3

19.2

25

25

8

8

10.5

50

3

4

5

29.2

40

40

8

8

15.3

25

200 - 240 (+ / - 10%) V 3 Phase Input, 3 Phase Output

1

0.37

0.5

3.4

6

6

8

8

2.3

-

1

0.75

1

5.6

10

10

8

8

4.3

-

1

1.5

2

8.9

16

15

8

8

7

-

2

1.5

2

8.9

16

15

8

8

7

100

2

2.2

3

12.1

16

17.5

8

8

10.5

50

3

4

5

20.9

32

30

8

8

18

25

3

5.5

7.5

26.4

40

35

8

8

24

20

4

7.5

10

33.3

40

45

16

5

30

15

4

11

15

50.1

63

70

16

5

46

10

380 - 480 (+ / - 10%)V 3 Phase Input, 3 Phase Output

1

0.75

1

3.5

6

6

8

8

2.2

-

1

1.5

2

5.6

10

10

8

8

4.1

-

2

1.5

2

5.6

10

10

8

8

4.1

250

2

2.2

3

7.5

16

10

8

8

5.8

200

2

4

5

11.5

16

15

8

8

9.5

120

3

5.5

7.5

17.2

25

25

8

8

14

100

3

7.5

10

21.2

32

30

8

8

18

80

3

11

15

27.5

40

35

8

8

24

50

4

15

20

34.2

40

45

16

5

30

30

4

18.5

25

44.1

50

60

16

5

39

22

4

22

30

51.9

63

70

16

5

46

22

NOTE

 Cable sizes shown are the maximum possible that may be connected to the drive. Cables should be selected 

according to local wiring codes or regulations at the point of installation.

Содержание OPTIDRIVE E3 Series

Страница 1: ...Quick Start Guide AC Variable Speed Drive IP66 NEMA 4X 0 37kW 22kW 0 5HP 30HP 1 10V 230V Single Phase input 230V 480V 3 Phase input Switched Non switched...

Страница 2: ...rrent x 10 2 PREPARE Prepare the Mounting Location The Optidrive must be mounted in a vertical position only Installation should be on a suitable flat flame resistant surface Do not mount flammable ma...

Страница 3: ...0 0 1 1 8 33 4 1 31 275 0 10 82 240 0 9 44 4 9 5 20 9 Mounting Clearance Drive Size X Above Below Y Either Side mm in mm in All Frame Sizes 200 7 87 10 0 39 NOTE Typical drive heat losses are approxim...

Страница 4: ...regulations Maximum dimensions are given in the Rating Tables section of this Quick Start Guide Install the Wiring L1 L L3 EMC Gland plate can be removed for installation L2 N U V W 1 2 3 4 5 6 7 8 9...

Страница 5: ...e side of this equipment and shall be rated 480Volt phase to ground 480 Volt phase to phase suitable for over voltage category iii and shall provide protection for a rated impulse withstand voltage pe...

Страница 6: ...ommon 10 RL1 Output Relay Function defined by P 18 See Parameter List 1 1 RL2 Output Relay Connection Example Factory Default Functions No Description DI1 0 1 Open Stop Closed Run DI2 Open Forward Rot...

Страница 7: ...ress the Navigate key for 1 second The display will show the motor power kW If P 10 0 pressing the Navigate key for 1 second will display the motor speed RPM Changing Parameters Press and hold the Nav...

Страница 8: ...7 Motor Rated Voltage Back EMF at rated speed PM BLDC 0 250 500 230 400 V P 08 Motor Rated Current Drive Rating Dependent A P 09 Motor Rated Frequency 10 500 50 60 Hz P 10 Motor Rated Speed 0 30000 0...

Страница 9: ...00 s P 25 Analog Output Function Select 0 11 8 Digital Output Mode Logic 1 24V DC Analog Output Mode 0 Drive Enabled Running 1 Drive Healthy 2 At Target Frequency Speed 3 Drive Tripped 4 Output Freque...

Страница 10: ...0 10 Unidirectional External 0 10Volt reference pot A 0 20 External 0 20mA signal t 4 20 External 4 20mA signal trip on loss r 4 20 External 4 20mA signal t 20 4 External 20 4mA signal trip on loss r...

Страница 11: ...9 2 25 25 8 8 10 5 50 3 4 5 29 2 40 40 8 8 15 3 25 200 240 10 V 3 Phase Input 3 Phase Output 1 0 37 0 5 3 4 6 6 8 8 2 3 1 0 75 1 5 6 10 10 8 8 4 3 1 1 5 2 8 9 16 15 8 8 7 2 1 5 2 8 9 16 15 8 8 7 100 2...

Страница 12: ...heatsink 17 Internal memory fault IO 18 4 20mA Signal Lost 19 Internal memory fault DSP 21 Motor PTC thermistor trip 22 Cooling Fan Fault IP66 only 23 Drive internal temperature too high 26 Output Fau...

Отзывы: