Purpose of the device

RFID MODBUS-10 is used to read the UNIQUE transponders code 
Transponder code is available using the MODBUS RTU protocol.

2 Warranty and liability of the manufacturer

The manufacturer provides a 2-year warranty on the module. The manufacturer also provides post-
warranty service for 10 years from the date of the introducing the module on the market. The 
warranty covers all defects in material and workmanship 

The manufacturer undertakes to comply with the contract of guarantee, if the following conditions 
are met::

all repairs, alterations, extensions and device calibrations are performed by the manufacturer
or authorized service, 

supply network installation meets applicable standards in this regard, 

the device is operated in accordance with the recommendations outlined in this manual

the device is used as intended.

The manufacturer assumes no responsibility for consequences resulting from improper installation, 
improper use of the module, not following this manual and the repairs of the module by individuals 
without permission. 

This device doesn’t contain serviceable parts. The repairs can be done only by manufacturers 
approved repair service. 

Содержание RFID-MB-10

Страница 1: ...User manual RFID MODBUS Reader RFID MB 10 INVEO s c ul Rzemie lnicza 21 43 340 Kozy tel 48 785552252 www inveo com pl info inveo com pl...

Страница 2: ...priate ways of dealing with this device the basic principles of safety and maintenance Please also keep the user manual so that you can read it during later use Remember The manufacturer is not liable...

Страница 3: ...ILISATION OF THE MODULEA 5 4 CONSTRUCTION EQUIPMENT 6 4 1 GENERAL FEATURES 6 5 DEVICE CONFIGURATION 7 5 1 OUT MODE 7 5 2 OUTPUT CONTROL OUT STATE TEST 8 5 3 READING CARD NUMBER CARD SERIAL NUMBER 8 5...

Страница 4: ...ct of guarantee if the following conditions are met all repairs alterations extensions and device calibrations are performed by the manufacturer or authorized service supply network installation meets...

Страница 5: ...midity from 30 to 75 atmospheric pressure is in the range 700 1060hPa Recommended conditions for transportation temperature from 10 C to 45 C humidity from 20 to 95 atmospheric pressure is in the rang...

Страница 6: ...15mA 12V Transponders Supported transponders UNIQUE Carrier frequency 125kHz Coding Manchester Reading distance 10cm Communication 1 port compatible with RS485 USB port for configuration Support MODBU...

Страница 7: ...ot required the device is fed through the USB port Drawing 1 Aplication window 5 1 OUT mode Mode Set the output mode selected from Static bistable mode Toggle momentary mode alternately turning on and...

Страница 8: ...hows the last read transponder code 5 4 RS485 Configuration of transmission RS485 The field is used to configure the device communication MODE setting 9 bit transmission None Odd Even Mark bit 1 the s...

Страница 9: ...R Software version 8 1007 Holding Reg R Hardware version 9 1008 Holding Reg R Output state after switching and in Safety mode 10 1009 Holding Reg R Time of communication failure followed by a transit...

Страница 10: ...04 appear random data Correct number shows only in the moment of reading new event indicated by setting the registry Single Coil 1004 1 read a new transponder The next reading of the transponder is on...

Страница 11: ...elay output max 1 A when 30 VDC max 0 5 A when 125 VAC RS485 Communication port Power LED LED indicates power connection to the module Status LED LED indicates operation of the relay USB USB port modu...

Страница 12: ...Notes...