Record: 0 – reset reading flag
20
1005
Single Coil
R/W
Status reset
Reading: 1 – there was a restart of the reader (ex.
through power failure)
Record: 1 – forcing a device reset
0 – Restart flag reset
21
1006
Single Coil
R/W
Safety status
Reading: 1 – Has been Safety mode triggered
Record: 0 – Flag reset
22
1007
Single Coil
R/W
RS485 status
Reading: 1 – Has beenTimeout of communication
RS485
Record 0 – Flag reset
23
1008
Single Coil
R
Input mode
Reading: 1 – active input, 0 – inactive input
(OPTION)
In case of no recording of new event of transponder code reading in Holding Register 1000-
1004 appear random data. Correct number shows only in the moment of reading new event,
indicated by setting the registry Single Coil 1004 (1- read a new transponder). The next reading of
the transponder is only possible after resetting the reading flag and entered „zero” into the 1004
register
Changing the output parameters for MODBUS, is not stored in it is stored in module volatile
memory. It means that after the restart or turn into the Safety mode there will be restored output
parameters previously writing to the EEPROM via USB.
Triggered of the Safety mode restores output settings stored in the EEPROM. It means that times of
switching on, of and output mode are overwritten. After exit Safety mode, if it's demanded all
output parameters should be set again by MODBUS