Make sure it is (good) finger-tight 

 as a loose heating coil can cause the MF3 to leak 

or display a heating coil error. 

 
7.

 

Re-fill the fluid tank and as with the first-time initial setup do allow the liquid to 
absorb for at least 30 minutes before using the MF3. 

 

NOTE:  

If during operation the MF3 

does not produce any smoke but you hear a ‘bubbling’ 

sound 

 STOP immediately as there is excessive fog liquid inside the heating coil.   

Try “flicking” the MF

3 away from you to expel the liquid from the barrel.  DO THIS OVER 

A SINK! 

  

 

 

 

.  Then try gently tapping the MF3 barrel on a flat surface to expel the liquid.  

If this does not work 

 you will need to change the heating coil. 

 

Troubleshooting 

No smoke is emitted even though the fan spins when you press the main button 

Ensure the heating coil is fully tightened. If the problem persists, 

carefully

 insert a fine 

screwdriver or other rod-like object into the barrel of the MicroFogger (the hole from which 
smoke is emitted) while the unit Rocker Switch is turned off.  

Briefly apply light pressure to the screwdriver, this will ensure that proper electrical contact 
is restored. Remove the screwdriver and try the unit again.  

Should this error persist, replace the coil with a new one. 

Fluid Tank Leaking 

Ensure both the heating coil and the tank are fully screwed home (finger tight).  If problem 
persists 

 ensure all white gaskets on the heating coil and the tank are properly and securely 

in place (and undamaged).

 

MicroFogger W

on’t 

Turn ON  

Plug it in to charge 

 remember use a mains fed USB charger outlet - (

with the 

Rocker/Toggle Switch 

‘ON’

) and wait at least 4 hours until the MicroFogger recharges. 

MicroFogger W

on’t 

Charge 

If the MF3 is in a critically low battery state, the battery state display may not show charged 
state for the first 30 minutes of charging.  If it still does not take/hold charge - please try 
using another charger and different micro-USB cable to diagnose whether it is an issue with 
the MF3 or not. 

 

 

Содержание MicroFogger 3 Pro

Страница 1: ...ise Double check that a coil is installed it usually is Using the 50ml bottle of fog liquid unscrew bottle cap Using the pipette style tip carefully pour fog liquid into the gap between the inner and outer walls of the reservoir DON T pour into the central part coloured RED in image Don t squeeze the bottle too hard or you ll overfill and spill the liquid Keep filling the fluid tank until the liqu...

Страница 2: ...tion to turn the MF3 on for charging or for operation Move to the 0 OFF position to completely turn the device off and especially for storage In the OFF position there will be little or no battery drain Mode Button lower Press to move between FAN SPEED and COIL POWER adjustment Hold down for 4 secs to enter Advanced Settings Menu In Advanced Settings Menu sequentially press to cycle through menu o...

Страница 3: ... be pressed again to begin adjusting the speed of the smoke fan power level in the same way as detailed above Throughout this process you can hold the trigger button to see how changes to these settings impact the smoke production in real time To return back to the home screen simply don t press the mode or select buttons for 2 seconds Advanced Settings Menu This interface can be entered by holdin...

Страница 4: ...tion By default all 4 Remote Control buttons are available pre programmed for use for various set power levels but once a specific letter is selected the MicroFogger will only be triggered when that button is pressed on the remote This allows for up to 4 independently controlled MicroFoggers RC Program Allows you to bind the MicroFogger to any 433mhz frequency remote control Simply press Select bu...

Страница 5: ... you observe this follow the instructions in the storage and maintenance section of this manual to replace the heating coil In extreme cases if you keep running the MicroFogger even after the heating coil has worn out small burning fragments of the absorbent material may be ejected out of the nozzle Although the MicroFogger can be used in any orientation provided that the tank is mostly full we st...

Страница 6: ...nk unscrewed ie off the MF3 during storage We always advise if storing for a few days or more to make sure that the tank is fully emptied to prevent the risk of leaks The fog fluid is non hazardous but a bit sticky During normal use a burning smell coming from the MF3 indicates that the heating coil should be replaced Follow the steps below To change the coil 1 Unscrew the MF3 from the fluid tank ...

Страница 7: ...a fine screwdriver or other rod like object into the barrel of the MicroFogger the hole from which smoke is emitted while the unit Rocker Switch is turned off Briefly apply light pressure to the screwdriver this will ensure that proper electrical contact is restored Remove the screwdriver and try the unit again Should this error persist replace the coil with a new one Fluid Tank Leaking Ensure bot...

Страница 8: ...n the first few second of operation with a new coil This is normal If the smell persists or becomes more noticeable stop using the MF3 and allow it to rest for at least another 30 minutes before switching on again Ensure that the fluid tank is fully filled In cold environments the fog liquid becomes more viscous thickens and will take longer to be absorbed into the heating coil In these situations...

Страница 9: ...ok directly into the MF3 s nozzle while it is running Finally a few more sensible guidelines that should be respected Never allow anyone under the age of 18 to use the MicroFogger 2 If the smoke starts smelling burnt immediately cease operation and replace the heating coil with a new one Never leave the MF3 in a car that is exposed to direct sunlight as during hot weather this is likely to cause t...

Страница 10: ... in this Manual and to use good judgement together with knowledge of the risks detailed above to safely operate the device If you are unwilling to accept the risks associated with using this device immediately return it for a full refund Support vosentech com Package Contents The following should be included with your standard MF3 Pro Dropper bottle with 50ml of fog liquid Replacement heating coil...

Страница 11: ... the micro USB port together To access these pins you can strip the end off a data transferring micro USB cable and then plug it into the MicroFogger WE can provide short cables to use for this purpose as an optional extra Typically when exposed these wires will be green and white but the colour can depend on the exact type of cable used For triggering it is normally the white and green wires that...

Страница 12: ...ditive and under normal operations the fog produced is considered to be non toxic However we do not recommend breathing in the smoke The smoke can only become potentially harmful to inhale if the safety precautions regarding the replacement of worn out heating coils are not followed What is the fog liquid The liquid consists of a high purity vegetable glycerine and propylene glycol mixture and is ...

Страница 13: ... to put it into cardboard or fabric enclosure you shouldn t encounter any issues On the other hand metal barrier such as car doors will usually block the signal although we have even had luck with activating the MicroFogger while it was inside a car hood Can I control the MicroFogger 2 via a wired remote Yes the usb charging port also doubles as a signal input which allows you to trigger the Micro...

Отзывы: