Quick Start - Operation
•
With the ON/OFF
rocker switch is set to ‘On’ –
then by pressing the main (large black)
button the MF3 produces smoke.
Remember - the MicroFogger 3 is designed to be an impulse device.
Using it continuously will make the heating coil wear out faster.
It is recommended that you use bursts of no longer than 10 seconds with 10 seconds rest
between bursts.
On-Board Controls & Operational Notes
Large Round Button
•
Hold down to start smoke production and release to stop.
•
Press once to return to the HOME screen from Advanced Settings Menu
Rocker/Toggle Switch
•
Move to
the I (“ON”) position to turn the
MF3 on for charging or for operation.
•
Move to the 0 (“OFF”) position to completely turn the device off (and especially for
storage).
In the “OFF” position there will be little or no battery drain.
Mode Button (lower)
•
Press to move between FAN SPEED and COIL POWER adjustment
•
Hold down for 4 secs to enter Advanced Settings Menu
•
In Advanced Settings Menu
–
sequentially press to cycle through menu options
Select Button (upper)
•
Press sequentially to cycle through the FAN/COIL power levels on the Home Screen
•
Press to cycle through individual settings adjustments in the Advanced Settings
Menu
•
On certain settings
–
HOLD to quickly cycle through number adjustments
Screen User Interface
•
The on-board Screen Interface will allow you change the MicroFogger
’
s power levels
and adjust various advanced settings. The overall structure of the Menu is as shown: