The working range of COOL mode and HEAT modeis
16
℃
-
30
℃
At DRY mode,the static pressure range is 0
~
25 pa.
When operating, the unit should be placed on the horizontal place, more
than 50cm away from the wall or other obstructions.
The working range of COOL
mode,Heat mode and DRY
mode.
Location requirement
Power supply
Before the unit is power-on, please check the following:
The power supply is rated voltage ±10%.
The power plugs and the sockets can be supported by the current
that is more than 16A.
The thread section of the lead wires and any continued use lead wire
is no less than 1.5mm2.
The air conditioner must be safety earthed. Earth wire must be
connected to the special device of the building. In order to provide
the good earthing for the air conditioner
.
The appliance must be positioned so that the plug is accessible,
If the supply cord is damaged, it must be replaced by the manufacturer
or its service agent or a similarly qualified person in order to avoid a hazard.
The appliance shall not be installed in the laundry.
The minimum clearance from the appliance to combustible surface is 50cm.
When children use the appliance, it must be supervised by adults or supervisors.
Including an air switch with suitable capacity, please note the following table. Air switch
should be included magnet buckle and heating buckle function, it can protect the
circuit-short and overload. (Caution: please do not use the fuse only for protect the circuit)
The appliance shall be installed in accordance with national wiring regulations.
The appliance is for indoor use only.
°
F
°
F
12K
16A
Air switch capacity