When AUTO RUN mode is selected, the setting temperature will not be displayed on the 

LCD, the unit will be in accordance  with the room temp. automatically to select the suitable 

running method and to make ambient comfortable.

About  turbo  function

If start this function, the unit will run at super-high fan speed to cool or heat quickly  so that

the ambient temp. approachs the preset temp. as soon as possible.

Press +and - buttons simultaneously to lock or unlock the keyboard. If the remote controller 

is locked, the icon

flicker for three times. If the keyboard is unlocked, the mark will disappear. 

About switch between Fahrenheit and Centigrade

Under status of unit off, press MODE and

-

buttons simultaneously to switch

 an d 

.

It indicates: after starting this function by remote controller and the unit has been under 
defrost status, If turn off the unit by remote controller, the unit will not stop defrosting until 
it is finished; if change setting mode by remote controller, the function ,which is set last 
time, won't be carried out until defrosting finished.

Operation of this function on or off: If remote controller is under off status, press mode button 

and X-FAN button simultaneously in order to enter or cancel this new function. If the unit is under 
defrost mode, dual eight position on remote controller will display H1.If switch to heat mode,
the position will display H1, which flickers for 5s, in which case, press  +/- button, H1 will 
disappear and  setting temp. be displayed. 

After remote controller is powered on, the new defrost function will be defaulted to be 
closed.

About lock

About AUTO RUN

About new function of defrosting(The appliance of the defrosting function is unavailable)  

        will be displayed on it, in which case, press any button, the mark will

1.

4.

2.

3.


Slightly to press the place with

  ,

 

along  the arrow  head direction to push the back cover of

  wireless 

 remote  control. (As show in figure)

Take out the old batteries. (As show in figure)

 Insert two new AAA1.5V dry batteries, and pay attention to the polarity. 
 (As show in figure)

 Attach the back cover of wireless remote control. (As show in figure)

When changing the batteries, do not use the old or different batteries,

If the wireless remote control will not be used for a long time, please 

otherwise, it can cause the malfunction of the wireless remote control.

take them out, and don't let the leakage liquid damage the wireless 
remote control.

The operation should be in its receiving range.

It should be placed at where is 1m away from the TV set or stereo sound sets.

If the wireless remote control can not operate normally, please take them out, 

 after 30s later and reinsert, if they cannot normally run, please change them.

Sketch map for 

changing batteries

NOTE:

Changing batteries and notices

OPERATION  OF THE REMOTE  CONTROLLER

Содержание MOB-GPC12AF

Страница 1: ...MOBILE AIR CONDITIONER MOB GPC12AF...

Страница 2: ...NCIPLE STRUCTURE OPERATING METHODS NAMES AND FUNCTIONS OF THE REMOTE CONTROLLER CARE AND MAINTENANCE TROUBLE SHOOTING USER NOTICES AFTER SERVICE OPERATIONOF THE REMOTE CONTROLLER 11 12 13 15 ACCESSORI...

Страница 3: ...ference and the technical parameters are subject to change without notice WORKING PRINCIPLE With the help of upper motor the airflow of indoor passes through the evaporator becomes the cooling wind bu...

Страница 4: ...2 STRUCTURE Front Rear Air outlet Controller panel Handle Remote box Upper air inlet grille Air exhaust outlet Lower air inlet grille...

Страница 5: ...provide the good earthing for the air conditioner The appliance must be positioned so that the plug is accessible If the supply cord is damaged it must be replaced by the manufacturer or its service a...

Страница 6: ...fuse the capability of the fuse must be appropriate In order to avoid the power cord damaged and electrical leakage do not fix the power supply on the knife edge or the sharp object The wiring must b...

Страница 7: ...to change the operation mode in order of L O O C DRY FAN HEAT No Heat mode for the cooling only unit 3 key In COOL and HEAT mode press once the SET TEMP will decrease 1 once the SET TEMP will increas...

Страница 8: ...her heat sources in the air Drain cap Drain port Install Drain Hose 1 Remove drain cap from drain port Drain Cap 2 Attach one end of the drain hose to the drain port with the clamp See Drain Hose grap...

Страница 9: ...5 Snap the free end of the drain hose into the drain hose clip Drain Hose Drain Hose Clip Drain port fixed clamp with screw Drain plug clip clip drain hose 7 OPERATING METHODS...

Страница 10: ...setting temp range is by pressing Swing up and down button below Press this button the running mode will change as Mode button MODE could turn on or turn off the Up and down swing function When unit i...

Страница 11: ...o change timing value quickly then remote controller will send out the signal immediately and hour on off will stop flickering If the time of that no press timer button under flickering status is abov...

Страница 12: ...in the displayer will be on When the LIGHT is off the icon will be disappeared and all the indicators light in the displayer will be off Light button LIGHT Press this button enter into SLEEP state wh...

Страница 13: ...ction on or off 5 Press TURBO button to set this function on or off Guide for operation optional operation Introduction for special function This function indicates that moisture on evaporator of indo...

Страница 14: ...remote controller will display H1 If switch to heat mode the position will display H1 which flickers for 5s in which case press button H1 will disappear and setting temp be displayed After remote cont...

Страница 15: ...recommended to use it with shortest length When installing exhaust pipe should be as flat as possible Don t prolong the pipe or connect it with other exhaust pipe or Correct installation is as shown i...

Страница 16: ...TALLATION OF HEAT EXHAUST HOSE following dimension bent too much it would easily cause malfunction 14 If the pipe are to be bent please install it by considering Wrong installation is shown in followi...

Страница 17: ...15 ACCESSORIES AND INSTALLATION OF HEAT EXHAUST HOSE PARTS INCLUDED Window Exhaust Adapter Rear plastic pipe end Flexible Exhaust Hose Front plastic pipe end...

Страница 18: ...of the unit has lots of dust the cleaning of air filter should be more frequently Disassembly and Cleaning Pull out the tab of the filter take out the air filter Wash the filter solely to spray like h...

Страница 19: ...use a cloth slightly moistened with water below 40 or the soap water or the water with cleanser after wresting wipe the dirt Do not use the gasoline diesel oil or the congeneric substance to clean the...

Страница 20: ...plug tightly 2 Ask for the electrician to replace 3 Ask for the electrician to replace the fuse 1 This is the normal phenomenon 2 Unit is running in defrosting operation it will come back to run in or...

Страница 21: ...use the health problems The unit should be placed about 1m or more away from the TV or it will be effected by the electromagnetic wave The air inlet outlet can t be blocked by the obstruction or it wi...

Страница 22: ...verturn If the abnormal phenomenon occurred please pull out the power plug at once and inform the dealer to check and maintain Do not use the insecticide or other sprays it can cause deformation or cr...