1   

, 2 hours later setting

temp.

NOTE: This remote controller is universal, it could be used for many units, some

buttons of this controller which are not available to this unit will not be 
described below.

X-FAN

 

button

Set X-FAN on (the character of X-FAN will 

appear)or off (the character of X-FAN dis-

appear) by pressing this key under cool

or dehumidify mode. Once energized,the

 unit will be defaulted to be X-FAN off.

This function can not be set under auto,

fan or heat mode, and the character of

X-FAN won't appear.

Note

X-FAN is the alternative expression 

of BLOW for the purpose of understanding.

Press this button to select LIGHT on or off

in the displayer. When the LIGHT is on, 
the icon     will be displayed and the indi-

cators' light in the displayer will be on.
When the LIGHT is off, the icon     will be
disappeared and all the indicators' light in
the displayer will be off.

Light button

LIGHT

Press this button, enter into SLEEP state, 

when repressed, it will quit. The sleep function

and FAN mode.

will be canceled with the stop of the unit. 

There is no SLEEP function under  AUTO 

is the icon for sleep 

function.

SLEEP

Sleep button

At COOL, DRY mode: the SLEEP mode runs 

after 1 hour, the setting temp. will be increased

by 1   (2     ),2 hour later, setting temp. will be  

increased by 2   

  (  4     )and then will run at  

this  setting temperature.

after 1 hour, the setting temp will be

At HEAT mode: the SLEEP mode runs

decreased by

  

then it will run at setting temperature.

will be decreased by 2

Remote controller

X-FAN

10

NAMES AND FUNCTIONS OF THE REMOTE CONTROLLER

°

F

°

F

(2   )

°

F

(4 

°

F)

FAN

AUTO

OPER

HEALTH

AIR

FILTER

TURBO

ON/OFF

X-FAN

HOUR

HUMIDITY

ON/OFF

MODE

FAN

X-FAN

TURBO

TEMP

TIMER

SLEEP

LIGHT

Содержание MOB-GPC12AF

Страница 1: ...MOBILE AIR CONDITIONER MOB GPC12AF...

Страница 2: ...NCIPLE STRUCTURE OPERATING METHODS NAMES AND FUNCTIONS OF THE REMOTE CONTROLLER CARE AND MAINTENANCE TROUBLE SHOOTING USER NOTICES AFTER SERVICE OPERATIONOF THE REMOTE CONTROLLER 11 12 13 15 ACCESSORI...

Страница 3: ...ference and the technical parameters are subject to change without notice WORKING PRINCIPLE With the help of upper motor the airflow of indoor passes through the evaporator becomes the cooling wind bu...

Страница 4: ...2 STRUCTURE Front Rear Air outlet Controller panel Handle Remote box Upper air inlet grille Air exhaust outlet Lower air inlet grille...

Страница 5: ...provide the good earthing for the air conditioner The appliance must be positioned so that the plug is accessible If the supply cord is damaged it must be replaced by the manufacturer or its service a...

Страница 6: ...fuse the capability of the fuse must be appropriate In order to avoid the power cord damaged and electrical leakage do not fix the power supply on the knife edge or the sharp object The wiring must b...

Страница 7: ...to change the operation mode in order of L O O C DRY FAN HEAT No Heat mode for the cooling only unit 3 key In COOL and HEAT mode press once the SET TEMP will decrease 1 once the SET TEMP will increas...

Страница 8: ...her heat sources in the air Drain cap Drain port Install Drain Hose 1 Remove drain cap from drain port Drain Cap 2 Attach one end of the drain hose to the drain port with the clamp See Drain Hose grap...

Страница 9: ...5 Snap the free end of the drain hose into the drain hose clip Drain Hose Drain Hose Clip Drain port fixed clamp with screw Drain plug clip clip drain hose 7 OPERATING METHODS...

Страница 10: ...setting temp range is by pressing Swing up and down button below Press this button the running mode will change as Mode button MODE could turn on or turn off the Up and down swing function When unit i...

Страница 11: ...o change timing value quickly then remote controller will send out the signal immediately and hour on off will stop flickering If the time of that no press timer button under flickering status is abov...

Страница 12: ...in the displayer will be on When the LIGHT is off the icon will be disappeared and all the indicators light in the displayer will be off Light button LIGHT Press this button enter into SLEEP state wh...

Страница 13: ...ction on or off 5 Press TURBO button to set this function on or off Guide for operation optional operation Introduction for special function This function indicates that moisture on evaporator of indo...

Страница 14: ...remote controller will display H1 If switch to heat mode the position will display H1 which flickers for 5s in which case press button H1 will disappear and setting temp be displayed After remote cont...

Страница 15: ...recommended to use it with shortest length When installing exhaust pipe should be as flat as possible Don t prolong the pipe or connect it with other exhaust pipe or Correct installation is as shown i...

Страница 16: ...TALLATION OF HEAT EXHAUST HOSE following dimension bent too much it would easily cause malfunction 14 If the pipe are to be bent please install it by considering Wrong installation is shown in followi...

Страница 17: ...15 ACCESSORIES AND INSTALLATION OF HEAT EXHAUST HOSE PARTS INCLUDED Window Exhaust Adapter Rear plastic pipe end Flexible Exhaust Hose Front plastic pipe end...

Страница 18: ...of the unit has lots of dust the cleaning of air filter should be more frequently Disassembly and Cleaning Pull out the tab of the filter take out the air filter Wash the filter solely to spray like h...

Страница 19: ...use a cloth slightly moistened with water below 40 or the soap water or the water with cleanser after wresting wipe the dirt Do not use the gasoline diesel oil or the congeneric substance to clean the...

Страница 20: ...plug tightly 2 Ask for the electrician to replace 3 Ask for the electrician to replace the fuse 1 This is the normal phenomenon 2 Unit is running in defrosting operation it will come back to run in or...

Страница 21: ...use the health problems The unit should be placed about 1m or more away from the TV or it will be effected by the electromagnetic wave The air inlet outlet can t be blocked by the obstruction or it wi...

Страница 22: ...verturn If the abnormal phenomenon occurred please pull out the power plug at once and inform the dealer to check and maintain Do not use the insecticide or other sprays it can cause deformation or cr...

Страница 23: ...CIRCUIT DIAGRAM 21 I1M 12...

Страница 24: ...66129910246...

Отзывы: