18
EN
|Troubleshooting
Please refer to the below prior to contacting customer support.
Problem
Possible Cause
Troubleshooting
Unit does not turn on when
pressing ON/OFF button
P1 Error Code
The Water Collection Tray is
full. Turn off the unit, drain
the water from the Water
Collection Tray and restart
the unit.
In COOL mode: room
temperature is lower than the
set temperature
Reset the temperature
Unit does not cool well
The air filter is blocked with dust
or debris
Turn off the unit and clean
the filter according to
instructions
Exhaust pipe is not connected
or is blocked
Turn off the unit, disconnect
the hose, check for blockage
and reconnect the hose
The unit is low on refrigerant
Call a service technician to
inspect the unit and top off
refrigerant
Temperature setting is too high Lower the set temperature
The windows and doors in the
room are open
Confirm all windows and exits
are shut
The room area is too large
Double-check the cooling
area
There are heat sources inside
the room
Remove the heat sources if
possible
The unit is noisy and vibrates
too much
The ground is not level
Place the unit on a flat, level
surface
The air filter is blocked with dust
or debris
Turn off the unit and clean
the filter according to
instructions
The unit makes a gurgling
sound
This sound is caused by the flow
of refrigerant inside the unit
This is normal
Содержание CLCO290-09
Страница 14: ...14 EN Operation Control panel NOTE The unit that you have purchased may look similar to one of the following ...
Страница 74: ...74 DE Wartung Control panel NOTIZ Ihr Klimagerät könnte wie ein von den unten angezeigten Geräten aussehen ...
Страница 114: ...114 IT Funzionamento Pannello di controllo NOTA l unità acquistata potrebbe sembrare come una delle seguenti ...
Страница 134: ...134 ES Guía de Funcionamiento NOTA La unidad que compró puede parecerse a una de las siguientes Panel De Control ...
Страница 142: ......
Страница 143: ......
Страница 144: ...144 EN PORTABLE AIR CONDITIONING SYSTEMS v 1 1 ...