Tear off the sticking stripe and then remove the
soundproof sponge.
Remove the 2 screws connecting the isolation plate
and condenser side plate; remove the 3 screws
connecting the isolation plate and chassis, and then
remove the isolation plate.
Unsolder the welding joints connecting
electronic
expansion valve assy
the 4-way valve assy with
capillary sub-assy, compressor and condenser;
remove the
electronic expansion valve assy
and
4-way valve.
Note:
Before unsoldering the welding joint, wrap the 4-way
valve with a wet cloth completely to avoid damage to
the valve caused by high temperature.
Steps
Procedure
8. Remove
4-way valve assy and
electronic expansion
valve assy
7. Remove isolation plate
6. Remove the soundproof sponge
soundproof sponge
isolation plate
4-way valve assy
electronic expansion
valve assy
114
Installation and Maintenance
Service Manual
Remove the 3 foot nuts fixing compressor and then
lift the compressor upwards to remove the
compressor and damping cushion.
Note:
Keep the ports of discharge pipe and suction pipe
from foreign objects.
Remove the screws connecting the support
(condenser) and condenser assy,and then remove
the support(condenser).
Remove the 2 screws fixing the condenser and
chassis, and then lift the condenser upwards to
remove it.
Steps
Procedure
10. Remove
condenser sub-assy
9. Remove compressor
compressor
support
condenser
chassis subassy
sub-assy
a
b